A comparison of blood collection in glass versus plastic vacutainers on results of esoteric coagulation assays
Flanders MM, Crist R, Rodgers GM
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection container material on hematological parameters of normal sodium citrate plasma specimens. Specimens were drawn sequentially into glass vacutainers first and then into plastic vacutainers.
Summary of Findings
The correlation between glass and plastic vacutainers was greater than 0.85 for all assays except TT. Plasma specimens collected in plastic vacutainers had increased TT, a slight increase in protein S activity, and a small decrease in factors XII, VII and VIII compared to specimens collected in glass vacutainers. However, only the increased TT when plasma was collected in plastic instead of glass was large enough to be clinically significant. Collecting specimens into plastic instead of glass vacutainers had no effect on the activity or antigen of Protein C, antithrombin, vonWillebrand factor, ristocetin cofactor, activated protein C resistance, fibrinogen activity, or coagulation factors II, V, IV, X or XI.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
ProteinELISAProteinHematology/ auto analyzerMorphologyHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Glass vacutainerPlastic vacutainer