Effect of pH on the stability of kidney injury molecule 1 (KIM-1) and on the accuracy of its measurement in human urine.
Pennemans V, De Winter LM, Faes C, Van Kerkhove E, Reynders C, Rigo JM, Swennen Q, Penders J
Purpose
The purpose of this paper was to determine the effects of pH on urinary kidney injury molecule 1 (KIM-1).
Conclusion
While significant decreases in KIM-1 were seen when urine was stored at pH values lower than 6 or higher than 8, the majority of these differences were eliminated when urinary pH was readjusted to 7 prior to measurement. However, a small but significant decline in percent recovery of KIM-1 was seen when specimens were stored at a pH of 4, even when urine was neutralized prior to analysis. The authors conclude that urinary pH has little effect on KIM-1 levels but that the ELISA kit used to measure KIM-1 is pH dependent.
Studies (1)
Purpose
The purpose of this study was to determine the effects of pH on urinary KIM-1. All specimens were stored, within 4 hours of collection, at -80 degrees C for up to 3 weeks prior to analysis.
Summary of Findings
While significant decreases in KIM-1 were seen when urine was stored at pH values lower than 6 or higher than 8, the majority of these differences were eliminated when urinary pH was readjusted to 7 prior to measurement. However, a small but significant decline in percent recovery of KIM-1 was seen when specimens were stored at a pH of 4, even when urine was neutralized prior to analysis. The authors concluded that urinary pH has little effect on KIM-1 levels but that the ELISA kit used to measure KIM-1 is pH dependent.
Biospecimens
FluidUrinePreservation Types
FrozenDiagnoses
NormalNot specifiedPlatforms
ProteinELISAElectrolyte/MetalpHPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Biomarker level Elevated KIM-1 values (2659 pg/mL)Normal KIM-1 values (438 pg/mL)Biospecimen Aliquots and Components pH 456789