Skip to main content

Factors reducing hemolysis rates in blood samples from the emergency department.

Munnix IC, Schellart M, Gorissen C, Kleinveld HA

Publication: Clin Chem Lab Med (2011) • Vol 49 • Page 157-8PMID: 20961194View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood specimen collection methods on hemolysis.

Conclusion

Hemolysis occurred in specimens from 16 out of 100 patients when blood was collected via IV catheter. In the 16 patients who had hemolyzed specimens, hemolysis was primarily noted in the 1st of 4 consecutively collected specimens (100%) while only 25% of the second collections showed hemolysis. IV placement on the hand was a major cause of hemolysis. Difficult catheter placement and use of a direct draw adapter also were associated with increased risk of hemolysis. Interestingly, needle gauge had no effects on hemolysis. No hemolysis was observed in specimens from 50 patients when blood was collected through venipuncture.

Studies (1)

Purpose

The purpose of this study was to compare hemolysis rates in blood specimens collected through IV catheter with those collected through venipuncture. Needle size, sequential collection, type of catheter, puncture site, and difficulty in catheter placement were also evaluated.

Summary of Findings

Hemolysis occurred in specimens from 16 out of 100 patients when blood was collected via IV catheter. In the 16 patients who had hemolyzed specimens, hemolysis was primarily noted in the 1st of 4 consecutively collected specimens (100%) while only 25% of the second collections showed hemolysis. IV placement on the hand was a major cause of hemolysis. Difficult catheter placement and use of a direct draw adapter also were associated with increased risk of hemolysis. Interestingly, needle gauge had no effects on hemolysis in this study. No hemolysis was observed in specimens from 50 patients when blood was collected through venipuncture.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    ProteinSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Anticubital vein
    Forearm
    Hand
    Left and right sides compared
    Biospecimen AcquisitionCannulation
    Difficult
    Direct draw adapter
    Eclipse needle with pre-attached holder
    Not difficult
    Biospecimen AcquisitionMethod of fluid acquisition
    IV catheter
    Venipuncture
    Biospecimen AcquisitionNeedle gauge
    18 gauge
    20 gauge
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    2nd collection
    3rd collection
    4th collection