Factors reducing hemolysis rates in blood samples from the emergency department.
Munnix IC, Schellart M, Gorissen C, Kleinveld HA
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to compare hemolysis rates in blood specimens collected through IV catheter with those collected through venipuncture. Needle size, sequential collection, type of catheter, puncture site, and difficulty in catheter placement were also evaluated.
Summary of Findings
Hemolysis occurred in specimens from 16 out of 100 patients when blood was collected via IV catheter. In the 16 patients who had hemolyzed specimens, hemolysis was primarily noted in the 1st of 4 consecutively collected specimens (100%) while only 25% of the second collections showed hemolysis. IV placement on the hand was a major cause of hemolysis. Difficult catheter placement and use of a direct draw adapter also were associated with increased risk of hemolysis. Interestingly, needle gauge had no effects on hemolysis in this study. No hemolysis was observed in specimens from 50 patients when blood was collected through venipuncture.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
ProteinSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw Anticubital veinForearmHandLeft and right sides comparedBiospecimen Acquisition Cannulation DifficultDirect draw adapterEclipse needle with pre-attached holderNot difficultBiospecimen Acquisition Method of fluid acquisition IV catheterVenipunctureBiospecimen Acquisition Needle gauge 18 gauge20 gaugeBiospecimen Aliquots and Components Aliquot sequential collection 1st collection2nd collection3rd collection4th collection