Archival fine-needle aspiration cytopathology (FNAC) samples: untapped resource for clinical molecular profiling.
Killian JK, Walker RL, Suuriniemi M, Jones L, Scurci S, Singh P, Cornelison R, Harmon S, Boisvert N, Zhu J, Wang Y, Bilke S, Davis S, Giaccone G, Smith WI Jr, Meltzer PS
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of prior staining of FNAC with DQ or Pap on DNA yield, size, and utility for microarray analysis. FNAC from suspected lymphoma and small cell lung carcinoma specimens were obtained from lower back, abdomen, thyroid, lung, thorax spleen, cervix, neck, submandibular glands, bronchus and retroperitoneum and stained 11-16 years prior to the study.
Summary of Findings
The yield of DNA obtained from DQ and PAP-stained FNAC was roughly equivalent, but while the DNA from PAP-stained specimens was almost all below 400 bp in length, DQ-stained specimens contained fragments up to 50,000 bp long. The DQ-stained specimens were successful for all profiling assays, and genomic structural aberrations were identified in 44 of 46 malignant smears. Despite the DNA degradation, similar genotyping and methylation results were obtained using PAP-stained specimens but with more background noise.
Biospecimens
CellLymph NodePreservation Types
Other PreservativeDiagnoses
NeoplasticBenignNeoplasticCarcinomaNeoplasticMixed typeNeoplasticLymphomaPlatforms
DNADNA microarrayDNAElectrophoresisMorphologyLight microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Pathology ink Diff-QuickPapanicolaouBiospecimen Preservation Type of fixation/preservation Air-driedAlcoholStorage Time at room temperature 11-16 yearsDNA microarray Specific Technology platform Agilent 105K or 180 K CGHIllumina Infinium 370K or 610K genotypingIllumina Infinium methylation 27K