The purpose of this paper was to determine the effects of room temperature storage and addition of protease inhibitors on plasma and serum peptide profiles and to determine whether differences exist between peptide profiles of myocardial infarction patients and normal subjects.
Processing of serum proteins underlies the mass spectral fingerprinting of myocardial infarction.
Marshall J, Kupchak P, Zhu W, Yantha J, Vrees T, Furesz S, Jacks K, Smith C, Kireeva I, Zhang R, Takahashi M, Stanton E, Jackowski G
Purpose
Conclusion
Sera from myocardial infarction patients showed a distinctive peptide profile when compared to sera from normal subjects. When plasma from normal subjects was left at room temperature, a difference in peptide patterns was visible by 4 hours. Incubation of normal serum with EDTA for 4 hours had no effect on peptide patterns, but PMSF had a concentration-dependent effect. At micromolar concentrations, PMSF had little effect on the peptide pattern, but at millimolar concentrations, it reduced the signal strength of the high mass peaks and increased signal complexity in the low mass ranges. When serum from normal subjects was left at room temperature with or without PMSF, differences between the peptide patterns were noted typically after 4 to 8 hours at room temperature. With time, the addition of PMSF eliminated most of the differences in peptide profiles between sera from myocardial infarction patients and from normal subjects.
Studies (1)
Purpose
The purpose of this study was to determine whether any differences exist between serum peptide profiles of myocardial infarction and normal patients. The effects of protease inhibitors and room temperature storage of plasma on peptide profiles were also examined. All specimens, other than the fresh specimens used for room temperature storage, were stored frozen at -70 degrees C and thawed once before this study.
Summary of Findings
Sera from myocardial infarction patients showed a distinctive peptide profile when compared to sera from normal subjects. These different profiles were seen with both MALDI-TOF and LC-ESI-ION TRAP analysis. When citrated-plasma from normal subjects was left at room temperature, a difference in peptide patterns was visible by 4 hours. Incubation of normal serum with EDTA for 4 hours had no effect on peptide patterns, but PMSF had a concentration-dependent effect. At micromolar concentrations, PMSF had little effect on the peptide pattern, but at millimolar concentrations, it reduced the signal strength of the high mass peaks and increased signal complexity in the low mass ranges. When serum from normal subjects was left at room temperature with or without PMSF, differences between the peptide patterns were noted typically after 4 to 8 hours at room temperature. With time, the addition of PMSF eliminated most of the differences in peptide profiles between sera from myocardial infarction patients and from normal subjects.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
FrozenDiagnoses
Cardiovascular DiseaseNormalPlatforms
PeptideMALDI-TOF MSProteinMALDI-TOF MSPeptideLC-ESI-ION TRAPProteinLC-ESI-ION TRAPPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Myocardial infarctionNormalBiospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Time at room temperature 0 h24 h4 h8 hAnalyte Extraction and Purification Protease inhibitor EDTAPMSF