Quality assurance in analysis of cryogenically stored liver tissue specimens from the NIST National Biomonitoring Specimen Bank (NBSB).

Mackey EA, Demiralp R, Fitzpatrick KA, Porter BJ, Wise SA, Becker PR, Greenberg RR

Publication: Sci Total Environ (1999) • Vol 226 • Page 165-76PMID: 10085566View on PubMed

Purpose

The purpose of this paper was to determine if the temperature (-80 or -150 degrees C) of long term specimen storage affects trace element composition.

Conclusion

No macroscopic evidence of specimen degradation was observed among cryopreserved liver specimens stored at either temperature. Specimen trace element composition (Rb, Fe, Zn) was unaltered by 17 years of storage at either storage temperature. The following elements were not altered by prolonged storage at either temperature, although several elements were at or below the detection limit of the platform: As, Mo, Cd, Sm, La.

Studies (1)

Purpose

The purpose of this study was to determine if the temperature (-80 or -150 degrees C) of long term specimen storage affects trace element composition. Subsets of five liver specimens snap-frozen and stored in pre-cleaned Teflon jars at -150 degrees in a liquid nitrogen vapor cooled freezer or a -80 degree C freezer for 17 years were examined.

Summary of Findings

No macroscopic evidence of specimen degradation was observed among cryopreserved liver specimens stored at either temperature. Specimen trace element composition (Rb, Fe, Zn) was unaltered by 17 years of storage at either storage temperature. The following elements were not altered by prolonged storage at either temperature, although several elements were at or below the detection limit of the platform: As, Mo, Cd, Sm, La.

  • Biospecimens

    TissueLiver
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalAtomic absorption spectroscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    17 y
    7 y
    StorageStorage temperature
    -150 degrees C
    -80 degrees C