The purpose of this paper was to determine the effects of preanalytical variables on urine peptide profiles.
Standardized peptidome profiling of human urine by magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
Fiedler GM, Baumann S, Leichtle A, Oltmann A, Kase J, Thiery J, Ceglarek U
Purpose
Conclusion
Peptide profiles were significantly changed when comparing fresh specimens to those that had been frozen, and in specimens collected on different days or in subsequent collections on the same day. Specimens contaminated with either blood or bacteria also had significantly different protein profiles. Once frozen, specimens showed stable peptide profiles, when stored at 4 degrees C, for up to 24 hours but were less stable at higher temperatures. Peptide patterns obtained using hydrophobic interaction chromatography beads were not pH dependent. However, weak cation-exchange chromatography beads and immobilized metal ion affinity chromatography beads gave the best yields and intensities at pH 7. Normalization of protein content by altering sample volume rather than dilution served to reduce inter-individual variation.
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage, freeze-thaw cycling, pH, contamination, dilution, and collection time on urine peptide profiles.
Summary of Findings
Freezing pooled urine specimens decreased relative peak intensities of some proteins while increasing others when compared to fresh pooled urine specimens, but further freeze-thaw cycling had little additional effects. Thawed frozen specimens were stable at 4 degrees C for 24 hours; however, these specimens showed significant changes in peptide patterns after 6 hours at 25 degrees C, or 3 hours at 40 degrees C. First morning urine had significantly higher total protein concentration and a distinct peptide profile when compared to second morning urine. Variations in peptide profile were also found when comparing specimens collected on different days. The addition of sodium chloride or urea up to a concentration of 1000 mmol/L did not alter specimen peptide patterns, but dilution with urea in order to normalize creatinine or protein concentrations resulted in a loss of mass signals and did not reduce variation. Normalization of protein content by altering sample volume rather than dilution served to reduce inter-individual variation. Blood contamination led to some new mass signals, while bacterial contamination led to decreases in signal intensities when incubated for at least 30 minutes. Peptide patterns obtained using hydrophobic interaction chromatography beads were not pH dependent, but weak cation-exchange chromatography beads and immobilized metal ion affinity chromatography beads gave the best yields and intensities at pH 7.
Biospecimens
FluidUrinePreservation Types
FrozenNone (Fresh)Diagnoses
NormalPlatforms
PeptideMALDI-TOF MSProteinMALDI-TOF MSProteinColorimetric assaySmall moleculeColorimetric assayCarbohydrateColorimetric assayElectrolyte/MetalClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Time of biospecimen collection Day 1Day 2Day 3Day 4Day 5Biospecimen Aliquots and Components Aliquot sequential collection 1st collection2nd collectionBiospecimen Aliquots and Components Biospecimen components Bacterial contaminationBlood contaminationSodium chlorideUreaWaterBiospecimen Aliquots and Components pH 6789Biospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Freeze/thaw cycling 1 cycle2 cycles3 cyclesStorage Storage duration 0 h1 h168 h24 h3 h6 h72 hStorage Storage temperature -80 degrees C25 degrees C4 degrees C40 degrees CMALDI-TOF MS Specific Resin Hydrophobic interaction chromatographyImmobilized metal ion affinity chromatographyWeak cation-exchange chromatography