The purpose of this paper was to determine the effects of anticoagulant, storage, and extraction method on retinol (ROH) levels in plasma and serum.
Analysis and stability of retinol in plasma.
Peng YM, Xu MJ, Alberts DS
Purpose
Conclusion
No difference between serum and herparin-plasma ROH levels were observed, but when EDTA was used as the anticoagulant a slight decrease in ROH recovery was observed. Storage of blood for up to 24 h, in the dark, on ice, prior to plasma separation, did not affect recovery of ROH. ROH in heparin-plasma was stable at -20 or -80 degrees C for at least 1 year. When ROH was extracted from spiked plasma, in the absence of perchloric acid, less than 50% of ROH was recovered; however, when perchloric acid was used, close to 100% recovery was attained. Once extracted from spiked plasma, ROH was stable for at least 4 h at room temperature, or 24 h at -20 degrees C, but decreased by 10% within the first hour of storage at 37 degrees C.
Studies (2)
Purpose
Summary of Findings
Biospecimens
FluidPlasmaPreservation Types
FrozenDiagnoses
NormalPlatforms
Small moleculeHPLCPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 h1 h2 h24 h4 hStorage Storage temperature -20 degrees C37 degrees CRoom temperatureAnalyte Extraction and Purification Analyte isolation method No perchloric acidPerchloric acid for 15 minPerchloric acid for 30 s
Purpose
The purpose of this study was to determine the effects of storage of blood or plasma and anticoagulant on endogenous ROH.
Summary of Findings
No difference between serum and herparin-plasma ROH levels were observed, but when EDTA was used as the anticoagulant, a slight decrease in ROH was observed. The use of oxalate or citrate as anticoagulant also led to decreased ROH. Storage of blood for up to 24 h in the dark, on ice, prior to plasma separation, did not affect recovery of ROH. ROH in heparin-plasma was stable at -20 or -80 degrees C for at least 1 year.
Biospecimens
FluidBloodFluidSerumFluidPlasmaPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Small moleculeHPLCPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant CitrateEDTAFluoride-oxalateLithium heparinBiospecimen Aliquots and Components Blood and blood products PlasmaSerumWhole bloodBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage conditions In the darkStorage Storage duration 0 h1 h12 months2 h24 h4 h6 monthsStorage Storage temperature -20 degrees C-80 degrees COn ice