The use of optimal cutting temperature compound can inhibit amplification by polymerase chain reaction.

Turbett GR, Sellner LN

Publication: Diagn Mol Pathol (1997) • Vol 6 • Page 298-303PMID: 9458390View on PubMed

Purpose

The purpose of this paper was to determine if OCT embedding impacts molecular analysis of frozen tissue specimens.

Conclusion

OCT embedding prior to freezing inhibited PCR amplification of 530 -763 bp gene fragments. PCR success rates worsened with extended extraction durations (2 h or longer) and were not improved by different extraction methods. RT-PCR analysis of an 346 bp amplification was successful among all specimens, suggesting RNA is not adversely affected by OCT embedding. Intentional contamination of purified nucleic acids extracted from control specimens produced thresholds for successful PCR-based analysis, although the authors note extenuating circumstances may be present for specimens exposed to OCT prior to freezing and nucleic acid extraction.

Studies (1)

Purpose

The purpose of this study was to determine if PCR-based analysis is affected by OCT embedding medium. A single tumor specimen was divided and preserved with or without OCT prior to freezing at -20 degrees C. The effects of intentional contamination of purified DNA and RNA with diluted OCT (0-10%) and the efficacy of different purification methods were also investigated.

Summary of Findings

PCR amplification of large gene products (530-763 bp) was unsuccessful for all specimens embedded in OCT prior to freezing, while specimens frozen in the absence of media had a 100% success rate for all amplicon sizes. PCR amplification of DNA extracted from OCT-embedded specimens was dependent on amplicon size as successful amplification of 96-280 bp gene products was observed. Washing OCT-embedded specimens prior to DNA extraction did not improve PCR success rate, although controls indicated that the saline wash was of no detriment. Intentional contamination of purified DNA extracted from control specimens resulted in failed amplification of the 763 bp product at a final OCT concentration of 5% or greater, with clear and appropriate amplification at OCT concentrations of 0-4%. PCR success rates remained unaffected by the extraction methods investigated, but were adversely affected by digestion (incubation) durations of 2 h or longer for OCT-embedded specimens or 24 h for specimens frozen in the absence of media, samples that also showed evidence of DNA degradation. RT-PCR analysis was successful for all specimens (with and without OCT) for the 346 bp amplicon. Successful RT-PCR analysis was inhibited by intentional OCT contamination of purified RNA at a final OCT concentration of 1%.

  • Biospecimens

    TissueSmall Bowel
  • Preservation Types

    OCTFrozen
  • Diagnoses

    NeoplasticLymphoma
  • Platforms

    DNAPCR
    DNAElectrophoresis
    RNART-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    OCT
    Analyte Extraction and PurificationAnalyte isolation method
    Ethanol precipitation
    Instagene matrix
    Phenol-chloroform extraction
    QIAamp tissue kit
    Analyte Extraction and PurificationIncubation duration/condition
    2-24 h
    RT-PCR SpecificLength of gene fragment
    346 bp
    RT-PCR SpecificReaction solution
    OCT (0-10%)
    PCR SpecificLength of gene fragment
    96-763 bp
    PCR SpecificReaction solution
    OCT (0-10%)