The purpose of this paper was to assess the utility of Hemogard Vacutainer tubes (Becton-Dickinson) containing boric acid, sodium formate, and sorbitol for the transportation and storage of urine specimens.
Microbiological evaluation of a commercial transport system for urine samples.
Eriksson I, Lindman R, Thore M
Purpose
Conclusion
Storage of urine in tubes containing boric acid, sodium formate, and sorbitol or refrigeration of urine served to inhibit bacterial growth both in experimentally infected urine and in specimens obtained from patients with suspected urinary tract infections.
Studies (2)
Purpose
The purpose of this study was to compare storage of urine in tubes containing boric acid, sodium formate, and sorbitol with storage in conventional tubes without bacteriostatic properties. Sterilized urine was experimentally infected with different microorganisms, and antibiotic solutions were added to the specimens.
Summary of Findings
During a 24 hour period, most microorganisms grew readily when urine was kept in conventional tubes stored at room temperature (21-23 degrees C). However, storage of urine in tubes containing borate-formate-sorbitol or storage at 2-8 degrees C inhibited bacterial growth. Further, borate-formate-sorbitol tubes showed decreasing counts of some bacterial strains after 24 hours and performed slightly better at 2-8 degrees C than at room temperature.
Biospecimens
FluidUrinePreservation Types
None (Fresh)Other PreservativeDiagnoses
NormalPlatforms
Cell count/volumeMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation Borate-formate-sorbitolNone (fresh)Storage Storage duration 0 h24 h3 h48 h6 h72 hStorage Storage temperature 2-8 degrees C21-23 degrees C
Purpose
The purpose of this study was to determine the effects of storage temperature and the use of tubes containing boric acid, sodium formate, and sorbitol on bacterial colony counts in urine specimens from patients with suspected acute urinary tract infections.
Summary of Findings
All bacterial counts increased between bedside culture (0 h) and arrival at the laboratory 3 to 28 h later; however, in urine specimens kept in conventional tubes at room temperature, the increase tended to be greater. When specimens were recultured after 24, 48, and 72 h, statistically significant increases in bacterial counts were seen for conventional tubes stored at room temperature when compared to those stored at 2-8 degrees C or tubes containing borate-formate-sorbitol.
Biospecimens
FluidUrinePreservation Types
None (Fresh)Other PreservativeDiagnoses
Other diagnosesPlatforms
Cell count/volumeMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Suspected acute urinary tract infectionBiospecimen Preservation Type of fixation/preservation Borate-formate-sorbitolNone (fresh)Storage Between site transportation method Not transportedUnspecified transport methodStorage Specimen transport duration/condition Chilled conventional tubeConventional tube at ambient temperatureHemogard vacutainer at ambient temperaturesStorage Storage duration 0 h24 h48 h72 hStorage Storage temperature 2-8 degrees C21-23 degrees C