Sample preparation and storage can change arsenic speciation in human urine.

Feldmann J, Lai VW, Cullen WR, Ma M, Lu X, Le XC

Publication: Clin Chem (1999) • Vol 45 • Page 1988-97PMID: 10545070View on PubMedSuggested by: ISBER

Purpose

The purpose of this paper was to asses the stability of arsenic species in urine during storage.

Conclusion

The stability of arsenic species was dependent on the urine source. Arsenic species were relatively stable in volunteer urine for up to 8 months at 4 degrees C, but approximately 30% of the arsenate was reduced after storage for 4 months at 4 degrees C when commercially purchased urine stabilized with sodium azide (standard urine) was used. Volunteer urine specimens showed the greatest stability when stored at 4 degrees C. Regardless of source, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and arsenobentaine (AsB) were more stable than arsenate which tended to be reduced to arsenite. Reducing urine pH to 4.5 prior to storage at 4 degrees C, or preservation with hydrochloric acid, sodium azide, benzoic acid, benzyltrimethyammonium chloride, methanol, or cetylpyridinium chloride had no beneficial effects.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration and temperature and the addition of preservatives on the stability of arsenic species in urine. Volunteer urine and freeze-dried or sodium azide preserved urine specimens obtained from commercial sources were spiked with arsenic species. Urine was also obtained from a study population exposed to arsenic through drinking water.

Summary of Findings

AsB was relatively stable with a maximum of 6% being converted to DMA and 2% to MMA after storage of urine for 8 months. The other arsenic species were relatively stable for up to 8 months at 4 degrees C in urine from volunteers or from environmentally exposed individuals, but less stable in standard urine. In standard urine, 30% of the arsenate was reduced to arsenite after 4 months at 4 degrees C. After storage at -20 degrees C, some volunteer urine specimens showed a substantial reduction in arsenic species, but the ratios were unaffected. Storage of volunteer urine at 25 degrees C for 1 month led to substantial increases in arsenite and reductions in MMA and arsenate. Reducing urine pH to 4.5 prior to storage at 4 degrees C had no effect on arsenic species. Preservation of the volunteer, but not standard urine with hydrochloric acid led to substantial conversion of arsenate to arsenite and a decrease in MMA and DMA recovery, regardless of storage temperature. While none of the other tested preservatives in volunteer urine led to a significant decrease in arsenic species stability, no increase in stability was noted either.

  • Biospecimens

    FluidUrine
  • Preservation Types

    FrozenOther Preservative
  • Diagnoses

    Not specified
    Normal
  • Platforms

    Electrolyte/MetalAtomic absorption spectroscopy
    Electrolyte/MetalHPLC-MS
    Electrolyte/MetalInductively coupled plasma mass spectrometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Benzoic acid
    Benzyltrimethyammonium chloride
    Cetylpyridinium chloride
    Hydrochloric acid
    Lyophilized
    Methanol
    Sodium azide
    StorageStorage conditions
    In the dark
    StorageStorage duration
    1 month
    2 months
    4 months
    8 months
    StorageStorage temperature
    -20 degrees C
    25 degrees C
    4 degrees C