Skip to main content

Fixation Time and Microwave Oven Irradiation Affect Immunocytochemical p53 Detection in Formalin-Fixed Paraffin Sections

Daidone MG, Benini E, Rao S, Pilotti S, Silvestrini R

Publication: Applied Immunohistochemistry (1998) • Vol 6 • Page 140-144

Purpose

The purpose of this paper was to determine the effects of formalin fixation duration and microwave antigen retrieval on p53 detection in breast carcinoma specimens.

Conclusion

Fixation for 24 hours required microwave antigen retrieval in order to obtain similar qualitative results as 6 hour fixation for p53 detection. However, when antigen retrieval was used, quantitatively more p53 positive cells were observed after the longer fixation time than with a 6 hour fixation with or without antigen retrieval. The three tested antibodies performed similarly.

Studies (1)

Purpose

The purpose of this study was to determine the effects of fixation duration and microwave antigen retrieval on p53 detection in formalin-fixed paraffin-embedded breast carcinoma specimens.

Summary of Findings

p53 immunostaining results were almost identical for three different antibodies. Among tissues fixed for 6 hours, there were no significant differences in p53 immunostaining with or without antigen retrieval. However, only 6 of 20 p53-postive tissue specimens fixed for 6 hours were also p53 positive after a 24 hour fixation without antigen retrieval. p53 staining was restored for 13 of the 14 p53-negative, 24 hour-fixed specimens when antigen retrieval was performed. Importantly, the percentage of p53 positive cells in 24 hour-fixed specimens after antigen retrieval was 1.5 to 8 times higher than the percentage of p53 positive cells in 6 hour-fixed specimens.
  • Biospecimens

    TissueBreast
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    ProteinImmunohistochemistry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationTime in fixative
    24 h
    6 h
    Analyte Extraction and PurificationAntigen retrieval
    Microwave irradiation
    None
    Immunohistochemistry SpecificTargeted peptide/protein
    p53
    Immunohistochemistry SpecificType of antibody
    CM1
    DO7
    PAb1801