Skip to main content

Stability studies of vorinostat and its two metabolites in human plasma, serum and urine.

Du L, Musson DG, Wang AQ

Publication: J Pharm Biomed Anal (2006) • Vol 42 • Page 556-64PMID: 16824724View on PubMedSuggested by: ISBER

Purpose

The purpose of this paper was to evaluate the stability of vorinostat, vorinostat O-glucuronide (M1) and 4-anilino-4-oxobutanoic acid (M2) in plasma, serum and urine specimens.

Conclusion

Storage of heparinized plasma at -70 degrees C for up to 5 weeks, serum for up to 57 weeks, or urine specimens for up to 58 weeks did not affect vorinostat or its metabolites. In neutral or acidified EDTA plasma, vorinostat declined by about 10% during the first week of storage at -70 degrees C but then stabilized. M1 was found to be more stable with storage in neutral plasma than acidified plasma, and M2 was relatively stable in both. Up to 3 freeze-thaw cycles had no effect on vorinostat, M1 or M2 levels in EDTA plasma, serum, or urine specimens. However, in heparinized plasma specimens, 3 freeze-thaw cycles led to an approximately 10% reduction in vorinostat levels. Storage of blood specimens for up to 180 minutes prior to centrifugation did not result in significant changes in serum concentrations of vorinostat, M1 or M2.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage and freeze-thaw cycling on vorinostat, M1 and M2 in neutral and acidified EDTA plasma, heparin plasma, serum and urine specimens. For all specimens vorinostat, M1 and M2 were added to the specimen prior to storage.

Summary of Findings

Storage of heparinized plasma at -70 degrees C for up to 5 weeks, serum for up to 57 weeks, or urine specimens for up to 58 weeks did not affect vorinostat or its metabolites. In neutral or acidified EDTA plasma, vorinostat declined by about 10% during the first week of storage at -70 degrees C but then stabilized. M1 was found to be more stable with storage in neutral plasma than acidified plasma, and M2 was relatively stable in both. Acidification of plasma specimens with formic acid led to decreased precision of the M1 and M2 assays, and acidification with high concentrations of acetic acid led to reduced precision and accuracy of M1 and M2 at low concentrations. Up to 3 freeze-thaw cycles had no effect on vorinostat, M1 or M2 levels in EDTA plasma, serum, or urine specimens. However, in heparinized plasma specimens, 3 freeze-thaw cycles led to an approximately 10% reduction in vorinostat levels. Little conversion between vorinostat, M1 and M2 in EDTA plasma specimens was observed. Storage of blood specimens for up to 180 minutes at room temperature prior to centrifugation did not result in significant changes in serum concentrations of vorinostat, M1 or M2.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidUrine
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    Small moleculeLC-MS or LC-MS/MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    EDTA
    Heparin
    Biospecimen AcquisitionBiospecimen location
    Plasma
    Serum
    Urine
    Biospecimen Aliquots and ComponentspH
    4.7
    7
    StorageFreeze/thaw cycling
    0 cycles
    3 cycles
    StorageStorage duration
    0 weeks
    1 week
    10 weeks
    2 weeks
    5 weeks
    57 weeks
    58 weeks
    7 weeks
    9 weeks
    StorageStorage temperature
    -70 degrees C
    StorageTime at room temperature
    120 min
    15 min
    180 min
    30 min
    60 min