Skip to main content

Effect of long-term freezer storage, thawing, and refreezing on selected constituents of serum.

DiMagno EP, Corle D, O'Brien JF, Masnyk IJ, Go VL, Aamodt R

Publication: Mayo Clin Proc (1989) • Vol 64 • Page 1226-34PMID: 2593713View on PubMed

Purpose

The purpose of this paper was to evaluate the effects of storage duration and freeze-thaw cycling on multiple analytes in serum.

Conclusion

After storage for up to 10 years or up to 6 freeze-thaw cycles, only very small changes which were likely to be clinically insignificant were observed in the assayed analytes.

Studies (1)

Purpose

The purpose of this study was to evaluate the effects of frozen storage for up to 10 years and up to 6 freeze-thaw cycles on electrolytes, hormones, vitamins, immunoglobulins, enzymes, and tumor markers in serum.

Summary of Findings

After storage for up to 10 years, only very small changes in analyte values which were likely to be clinically insignificant were observed. While electrolytes tended to increase with storage, enzymes tended to decrease, but the values remained within normal ranges. Similarly, freeze-thaw cycling generally resulted in small clinically insignificant changes. Lactate dehydrogenase (LDH) and creatinine kinase (CK) concentrations were both decreased when specimens underwent 4 freeze-thaw cycles where thawing occurred at room temperature for 4 h. LDH was also decreased in specimens after 4 freeze-thaw cycles with a 30 minute thaw at room temperature.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    NeoplasticBenign
    Normal
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    PeptideClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
    GlycoproteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    4 cycles
    6 cycles
    StorageStorage duration
    1 year
    10 years
    2 years
    3 years
    4 years
    5 years
    6 years
    7 years
    8 years
    9 years
    StorageStorage temperature
    -70 degrees C
    StorageThaw duration
    30 min
    4 h