Storage conditions of blood samples and primer selection affect the yield of cDNA polymerase chain reaction products of hepatitis C virus.
Cuypers HT, Bresters D, Winkel IN, Reesink HW, Weiner AJ, Houghton M, van der Poel CL, Lelie PN
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to compare the use of fresh-frozen plasma with serum for the detection of HCV by RT-PCR and to examine the effectiveness of different primers.
Summary of Findings
In fresh-frozen plasma specimens, the 5'-TR PCR primers were 10-100 times more effective at amplifying HCV RNA than the NS3/NS4 PCR primers. HCV detection occurred in 67% of plasma specimens using the NS3/NS4 PCR primers, but only in 50% of serum specimens. The use of the 5'TR PCR primers increased detection of HCV to 92% in plasma and to 75% in serum. 5'TR PCR products from two of the three serum specimens which were negative by ethidium bromide staining but positive in plasma specimens were detected in serum by southern transfer. In conclusion, RT-PCR detection of HCV is more sensitive in fresh-frozen plasma than in serum.
Biospecimens
FluidPlasmaFluidSerumPreservation Types
FrozenDiagnoses
HepatitisPlatforms
RNART-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaSerumBiospecimen Preservation Type of fixation/preservation FrozenSnap frozenStorage Storage temperature -20 degrees C-70 degrees CRT-PCR Specific Targeted nucleic acid 5' terminal regionNS3/NS4
Purpose
The purpose of this study was to determine the effects of storage of EDTA-whole blood at room temperature or serum at room temperature or 4 degrees C on the detection of HCV by RT-PCR with two different primer sets. After the experimental storage of whole blood or serum, plasma was prepared from whole blood and both serum and plasma were stored at -70 degrees C.
Summary of Findings
Serum specimens were more stable than EDTA whole blood when stored at either 4 degrees C or room temperature. For one plasma specimen, the NS3/NS4 RT-PCR product was lost after storage of EDTA-whole blood for only 1 day at room temperature. In contrast, the NS3/NS4 product was detected in all 3 serum specimens after 14 days of storage at 4 degrees C or 3 days of storage at room temperature. The 5'TR PCR product was detected in plasma when whole blood specimens were stored at room temperature for at least 6 days and in serum stored at room temperature for at least 8 days. No loss of the 5'TR PCR product was observed in serum stored at 4 degrees C for 14 days.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
FrozenDiagnoses
HepatitisPlatforms
RNART-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaSerumWhole bloodBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage duration 0 days1 day14 days2 days3 days4 days6 days8 daysStorage Storage temperature 4 degrees CRT-PCR Specific Targeted nucleic acid 5' terminal regionNS3/NS4