Skip to main content

Serum biobank certification and the establishment of quality controls for biological fluids: examples of serum biomarker stability after temperature variation.

Chaigneau C, Cabioch T, Beaumont K, Betsou F

Publication: Clin Chem Lab Med (2007) • Vol 45 • Page 1390-5PMID: 17635068View on PubMed

Purpose

The purpose of this paper was to examine the effects of freeze-thaw cycling and storage at 37 degrees C on serum biomarkers from 2 healthy individuals.

Conclusion

Little variation was observed in metalloprotease 7 (MMP-7) for up to 10 freeze-thaw cycles, or in anti-HBs Immunoglobulin G (anti-HBS) and transforming growth factor b1 (TGF-beta1) for up to 100 freeze-thaw cycles, but freezing of serum led to an immediate decrease (18-43%) in secretory phospholipase A2 (PLA). On the other hand, storage of serum at 37 degrees C resulted in an immediate increase in PLA. In one of the two specimens, storage at 37 degrees C also increased anti-HBS and TGF-beta1 levels. In contrast, MMP-7 was relatively stable in both specimens for 3 days, but then degradation occurred in one specimen while the other remained within 17% of baseline for the full 8 days studied.

Studies (1)

Purpose

The purpose of this study was to examine the effects of up to 100 freeze-thaw cycles and storage at 37 degrees C for up to 10 days on serum biomarkers.

Summary of Findings

Little variation was observed in MMP-7, anti-HBS or TGF-beta1 for up to 10 freeze-thaw cycles, but freezing of serum led to an immediate decrease (18-43%) in PLA activity which remained below baseline until 10-15 freeze-thaw cycles. TGF-beta1 remained within 5% of baseline and anti-HBS within 30% of baseline for up to 100 freeze-thaw cycles. After 15 freeze-thaw cycles, PLA increased and stabilized at 359%-505% of baseline. In contrast, MMP-7 decreased rapidly after 10-20 freeze-thaw cycles and was completely degraded by 30 cycles. Storage of serum at 37 degrees C resulted in an immediate increase in PLA which remained at 260-400% of baseline for the 10 days studied. MMP-7 was relatively stable in both specimens for 3 days, at which point degradation occurred in one specimen while the other remained within 17% of baseline for the full 8 days studied. Both anti-HBS and TGF-beta1 were elevated with storage at 37 degrees C in one specimen, while the other specimen remained constant for the full 6 (anti-HBS) or 4 (TGF-beta1) days studied.

  • Biospecimens

    FluidSerum
  • Preservation Types

    FrozenNone (Fresh)
  • Diagnoses

    Normal
  • Platforms

    ProteinEnzyme assay
    ProteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    10 cycles
    100 cycles
    15 cycles
    2 cycles
    20 cycles
    3 cycles
    30 cycles
    4 cycles
    40 cycles
    5 cycles
    50 cycles
    60 cycles
    70 cycles
    80 cycles
    90 cycles
    StorageStorage duration
    0 days
    1 days
    10 days
    2 days
    3 days
    4 days
    5 days
    6 days
    7 days
    8 days
    9 days
    StorageStorage temperature
    -80 degrees C
    37 degrees C
    ELISA SpecificTargeted peptide/protein
    Matrix metalloprotease 7
    Secretory phospholipase A2
    Transforming growth factor beta 1
    anti HBs immunoglobulin G