Skip to main content

Comparison of three DNA extraction methods on bone and blood stains up to 43 years old and amplification of three different gene sequences.

Cattaneo C, Craig OE, James NT, Sokol RJ

Publication: J Forensic Sci (1997) • Vol 42 • Page 1126-35PMID: 9397557View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage, extraction method, and targeted nucleic acid on the extraction of amplifiable DNA from bone and blood specimens.

Conclusion

Amplifiable DNA was obtained more often from dried-blood specimens than bone specimens in which a significant decline in amplifiability was noted in the first 10 years of storage. DNA extracted using the glass milk method had the highest rate of amplification success (65%) followed by DNA extracted with sodium acetate (55%) and magnetic beads (37%). Sodium acetate extraction yielded the largest quantity of DNA, but resulted in significant PCR inhibition (24%) in contrast to the low PCR inhibition observed when extraction was performed using glass milk (6%) or magnetic beads (11%). Mitochondrial DNA was most often successfully amplified (84%). No differences were observed between HLA DPB1 (39%) and amelogenin (35%) amplification despite the shorter amplicon length of amelogenin (106 bp versus 327 bp).

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage, extraction method, targeted nucleic acid and amplicon size on the extraction of amplifiable DNA from bone and blood specimens. Blood smears were dried and stored at room temperature for 0-26 years. Bone specimens were obtained fresh, stored for 3-6 years at 4 degrees C, or interred for up to 40 years then stored at ambient temperatures for 5 years followed by storage at -80 degrees C.

Summary of Findings

Amplifiable DNA was obtained more often from dried-blood specimens than bone specimens in which a significant decline in amplifiability was noted in the first 10 years of storage. DNA extracted using the glass milk method had the highest rate of amplification success (65%) followed by DNA extracted with sodium acetate (55%) and magnetic beads (37%). Sodium acetate extraction yielded the largest quantity of DNA, but resulted in significant PCR inhibition (24%) in contrast to the low PCR inhibition observed when extraction was performed using glass milk (6%) or magnetic beads (11%). Mitochondrial DNA was most often successfully amplified (84%). No differences were observed between HLA DPB1 (39%) and amelogenin (35%) amplification despite the shorter amplicon length of amelogenin (106 bp versus 327 bp).

  • Biospecimens

    TissueBone
    FluidBlood
  • Preservation Types

    None (Fresh)Other PreservativeFrozen
  • Diagnoses

    Autopsy
    Not specified
  • Platforms

    DNAPCR
    DNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionBiospecimen location
    Blood
    Bone
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Frozen
    None (fresh)
    Refrigeration
    StorageStorage duration
    0 years
    13-43 years
    3-6 years
    Analyte Extraction and PurificationAnalyte isolation method
    Glass milk
    Magnetic beads
    Sodium acetate
    PCR SpecificLength of gene fragment
    106/112 bp
    327 bp
    PCR SpecificTargeted nucleic acid
    Amelogenin
    HLA DPB1
    Mitochondrial