Genomic profiling by DNA amplification of laser capture microdissected tissues and array CGH.
Cardoso J, Molenaar L, de Menezes RX, Rosenberg C, Morreau H, Möslein G, Fodde R, Boer JM
Purpose
The purpose of this paper was to determine the compatibility of phi29 amplification of laser capture microdissected (LCM) colon mucosa DNA with detection of DNA copy number changes by microarray.
Conclusion
Comparison of copy number in amplified and nonamplified LCM DNA showed reproducible alterations particularly in telomeres, centromeres and other repetitive areas. However, no changes were found when a comparison was made between two separately dissected and amplified DNA samples. Microarray analysis of normal colon mucosa specimens revealed lower than expected sex chromosome differences when phi29 amplified DNA was used. Importantly, microarray analysis of an adenoma specimen from a patient with familial adenomatous polyposis (FAP) correctly identified loss of heterozygosity at the APC locus which is associated with FAP. The authors conclude that the quality of phi29 amplified LCM DNA is suitable for microarray analysis detection of copy number changes.
Studies (1)
Purpose
The purpose of this study was to determine whether phi29 amplification of LCM colon mucosa DNA is suitable for detection of copy number changes by microarray analysis.
Summary of Findings
One thousand LCM colon cells yielded 5-10 ng genomic DNA. After Phi29 amplification, yield was increased to 1250-6250 ng. Comparison of copy number in amplified and nonamplified LCM DNA showed reproducible alterations particularly in telomeres, centromeres and other repetitive areas. However, no changes were found when a comparison was made between two separately dissected and amplified DNA samples. Microarray analysis of normal colon mucosa specimens revealed lower than expected sex chromosome differences when phi29 amplified DNA was used. Importantly, microarray analysis of an adenoma specimen from a patient with familial adenomatous polyposis (FAP) correctly identified loss of heterozygosity at the APC locus which is associated with FAP. The authors conclude that the quality of phi29 amplified LCM DNA is suitable for microarray analysis detection of copy number changes.
Biospecimens
TissueColorectalPreservation Types
EthanolDiagnoses
NormalNeoplasticBenignPlatforms
DNAWhole genome amplificationDNADNA microarrayDNAPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Patient gender FemaleMaleBiospecimen Aliquots and Components Cell capture method Laser capture microdissectionWhole genome amplification Specific Nucleic acid amplification Not amplifiedPhi29 amplifiedPCR Specific Targeted nucleic acid TH01