Stability studies of twenty-four analytes in human plasma and serum.

Boyanton BL Jr, Blick KE

Publication: Clin Chem (2002) • Vol 48 • Page 2242-7PMID: 12446483View on PubMed

Purpose

The purpose of this paper was to determine the effects of prolonged contact of plasma or serum specimens with blood cells on clinical chemistry analytes.

Conclusion

No clinically significant changes occurred in plasma or serum with storage at room temperature of up to 56 hours after double centrifugation of blood specimens to remove cells. However, clinically significant changes with prolonged storage of uncentrifuged blood were observed in plasma but not serum for total carbon dioxide (tCO2) after 48 h, total protein (TP) after 24 h, calcium after 32 h, alanine aminotransferase (ALT) after 40 h, total cholesterol (TC) after 24h, magnesium (Mg) after 40 h, and gamma-glutamyltransferase (GGT) after 40h. After prolonged storage of blood at room temperature, clinically significant changes were observed for both plasma and serum in potassium (K) after 24 h, glucose after 30 min, creatinine after 24 h, albumin after 40 h, phosphorous (P) after 24 h, urate after 24h, lactate dehydrogenase (LD) after 8 h, lactate after 30 min, pH after 30 min, partial pressure of carbon dioxide (PCO2) after 4 h, and the partial pressure of oxygen (PO2) after 4 h. Although free hemoglobin was elevated in plasma and serum after delayed centrifugation, the values remained far below levels necessary to interfere with bilirubin and creatinine kinase (CK) assays.

Studies (1)

Purpose

The purpose of this study was to determine the effects of prolonged contact of plasma or serum specimens with blood cells on 24 clinical chemistry analytes.

Summary of Findings

No clinically significant changes with room temperature storage of up to 56 hours occurred in separated plasma or serum specimens. However, clinically significant changes with prolonged storage of uncentrifuged blood were observed in plasma but not serum for tCO2 after 48 h, TP after 24 h, calcium after 32 h, ALT after 40 h, TC after 24h, Mg after 40 h, and GGT after 40h. Clinically significant changes with delayed centrifugation of either plasma or serum occurred in K after 24 h, glucose after 30 min, creatinine after 24 h, albumin after 40 h, P after 24 h, urate after 24 h, LD after 8 h, lactate after 30 min, pH after 30 min, PCO2 after 4 h, and the PO2 after 4 h. Although free hemoglobin was elevated in plasma and serum after delayed centrifugation, the values remained far below levels necessary to interfere with bilirubin and CK assays. In conclusion, delayed centrifugation of blood specimens stored at room temperature resulted in changes in most serum and plasma analytes. However, plasma analytes tended to be slightly more unstable than serum analytes.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Small moleculeClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
    LipidClinical chemistry/auto analyzer
    Small moleculepH
    ProteinHematology/ auto analyzer
    GasClinical chemistry/auto analyzer
    MorphologyMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage conditions
    In the dark
    StorageTime at room temperature
    16 h
    24 h
    30 min
    32 h
    4 h
    40 h
    48 h
    56 h
    8 h