Stability studies of twenty-four analytes in human plasma and serum.
Boyanton BL Jr, Blick KE
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of prolonged contact of plasma or serum specimens with blood cells on 24 clinical chemistry analytes.
Summary of Findings
No clinically significant changes with room temperature storage of up to 56 hours occurred in separated plasma or serum specimens. However, clinically significant changes with prolonged storage of uncentrifuged blood were observed in plasma but not serum for tCO2 after 48 h, TP after 24 h, calcium after 32 h, ALT after 40 h, TC after 24h, Mg after 40 h, and GGT after 40h. Clinically significant changes with delayed centrifugation of either plasma or serum occurred in K after 24 h, glucose after 30 min, creatinine after 24 h, albumin after 40 h, P after 24 h, urate after 24 h, LD after 8 h, lactate after 30 min, pH after 30 min, PCO2 after 4 h, and the PO2 after 4 h. Although free hemoglobin was elevated in plasma and serum after delayed centrifugation, the values remained far below levels necessary to interfere with bilirubin and CK assays. In conclusion, delayed centrifugation of blood specimens stored at room temperature resulted in changes in most serum and plasma analytes. However, plasma analytes tended to be slightly more unstable than serum analytes.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Small moleculeClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerSmall moleculepHProteinHematology/ auto analyzerGasClinical chemistry/auto analyzerMorphologyMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaSerumWhole bloodBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage conditions In the darkStorage Time at room temperature 16 h24 h30 min32 h4 h40 h48 h56 h8 h