Stability of activated partial thromboplastin time (APTT) test under different storage conditions.
Awad MA, Eldeen OA, Ibrahim HA
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage duration and temperature on APTT and FVIII activity in plasma specimens from healthy volunteers and cardiovascular disease patients.
Summary of Findings
For healthy subjects, no significant changes were observed in APTT when plasma was either stored at room temperature or 4 degrees C for up to 6 hours, but increasing APTT was observed with storage at -40 degrees C or when specimens were stored for more than 6 h at room temperature or 4 degrees C. In contrast, for cardiovascular disease patients receiving heparin therapy, APTT test results increased significantly with storage at all temperatures (p<0.05). FVIII activity in healthy patients was significantly lower for all temperatures and storage durations compared to zero time values (p<0.05).
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalCardiovascular DiseasePlatforms
MorphologyHematology/ auto analyzerProteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition After heart surgeryHealthyMyocardial infarctUnstable anginaPreaquisition Other drugs Unfractionated heparin therapy for 1 dayUnfractionated heparin therapy for 2 daysBiospecimen Acquisition Anticoagulant Sodium citrateStorage Storage duration 0 h12 h24 h6 hStorage Storage temperature -40 degrees C4 degrees CRoom temperature