Instability of frozen human erythrocytes at elevated temperatures
Sun WQ, Wagner CT, Livesey SA, Conner J
Publication: Cell Preservation Technology (2003) • Vol 1 • Page 255
Purpose
The purpose of this paper was to determine the effects of isothermal storage, thawing, and dilution on hemolysis of cryopreserved erythrocytes.
Conclusion
Hemolysis of cryopreserved erythrocytes after thawing was 6.1 +/- 0.4%. After a single-step 10-fold dilution of thawed erythrocytes in phosphate-buffered saline (PBS), hemolysis increased to around 33%, whereas a 3-step 30-fold dilution resulted in only 12 +/- 2% hemolysis. Hemolysis increased with longer isothermal storage at higher temperatures, but at each temperature, a plateau was reached where longer storage did not further increase hemolysis.
Studies (1)
Purpose
The purpose of this study was to determine the extent to which thawing, dilution, and isothermal storage of cryopreserved erythrocytes affect hemolysis. Erythrocytes were stored at 4 degrees C prior to cryopreservation, and 10-25 days had elapsed since blood collection prior to the start of the study.
Summary of Findings
Hemolysis of cryopreserved erythrocytes after thawing was 6.1 +/- 0.4%. After a single-step 10-fold dilution of thawed erythrocytes in PBS, hemolysis increased to around 33%, whereas a 3-step 30-fold dilution resulted in only 12 +/- 2% hemolysis. Hemolysis increased with longer isothermal storage at higher temperatures, but at each temperature, a plateau was reached where longer storage did not further increase hemolysis. These plateau hemolysis values were approximately 12% by 20 days at -78 degrees C, 10% by 4 days at -62 degrees C, 28% by 3 days at -52 degrees C, 28% by 1 hour at -46 degrees C, 30% by 12 hours at -17 degrees C, 75% by 16 hours at -15 degrees C, and 100% by 3 hours at -13 degrees C.
Biospecimens
CellBloodPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
ProteinSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot size/volume Single-step dilutionThree-step dilutionStorage Storage duration 0-24 h (-15, -17 degrees C)0-4 h (-46 degrees C)0-5 d (-62 degrees C)0-70 d (-78 degrees C)0-8 h (-13 degrees C)0-9 d (-52 degrees C)Storage Storage temperature -13 degrees C-15 degrees C-17 degrees C-196 degrees C-46 degrees C-52 degrees C-62 degrees C-78 degrees C