Long-term storage of fresh frozen plasma at -40 degrees C. A multicenter study on the stability of labile coagulation factors over a period of 3 years
Illert WE, Butsch H, Nuber D, Howe J, Sanger W, Weidinger S
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine whether storing plasma specimens at -40 +/-2 degrees C over a period of 37 months affects coagulation factor activity. Preparation of all plasma specimens was completed at 20-24 degrees C within 18 hours at which point specimens were frozen. Analysis was performed at 7 different labs.
Summary of Findings
Without taking ABO blood groups into consideration, coagulation factor FXI and AT III had no significant loss in activity over 37 months of storage at -40 degrees C. In contrast, the activity of coagulation factors FV and FVIII:C declined significantly (0.6 and 9%, respectively). When individual ABO blood groups were considered, it was noted that group A showed an increase in AT III activity of 11% after 37 months and group O showed an increase in FXI activity of 11.2% at the end of the storage period. However, the authors conclude that storage of plasma at -40 degrees C for up to 3 years did not cause any clinically relevant losses in coagulation factor activity.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
MorphologyHematology/ auto analyzerProteinSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Patient genotype Blood type ABlood type ABBlood type BBlood type OStorage Storage duration 1 month12 months16 months20 months24 months28 months32 months37 months4 months8 monthsStorage Storage temperature -38 to -42 degrees C