Influence of Blood Specimen Collection Method on Various Preanalytical Sample Quality Indicators

Ashavaid TF, Dandekar S, Keny B, Bhambhwani VR

Publication: Indian Journal of Clinical Biochemistry (2008) • Vol 23 • Page 144

Purpose

The purpose of this paper was to compare preanalytical specimen quality factors among specimens collected using an evacuated blood collection device or using an open collection method (needle and syringe) with disposable tubes or reusable glass vials.

Conclusion

Collection of blood using the evacuated collection system and a laboratory/hospital information system, rather than open collection and manual data management, dramatically reduced specimen ID and tracking related errors, specimen volume errors, spillage, hemolysis, contamination, and the occurrence of post-centrifugation fibrin clots.

Studies (1)

Purpose

The purpose of this study was to compare various preanalytical specimen quality indicators using blood specimens collected either through open collection using a needle and syringe with either disposable tubes or re-useable glass vials, or through closed collection using the BD Vacutainer blood collection system including vacuum tubes. Evaluated specimen quality indicators included loss of specimen, loss of order form, specimen ID/order form mismatch, missing specimen ID, insufficient specimen volume, collection container over- or under-filled, specimen contaminated, fibrin clot after centrifugation, and hemolysis. In addition, the use of a laboratory/hospital information system to keep track of reports and requisition forms was compared to manual data management.

Summary of Findings

For every specimen quality variable that was evaluated, the use of BD Vacutainer closed collections, compared with open syringe/needle collection into either a BD Vacutainer disposable tube or a glass vial, resulted in significantly less incidences per 10,000 specimens (extrapolated numbers) with two exceptions. For 3 specimens out of 10,000 using the closed collection method, the tubes were overfilled, and this never occurred after open collection. Also, while 0 specimens collected via the closed method leaked, only 1 in 10,000 leaked after open collection which is not as significant an improvement as seen for the other variables. Importantly only 6 in 10,000 closed collected specimens showed any degree of hemolysis (visually identified through serum color), and only 3 in 10,000 were contaminated. For specimens collected via open collection, 563 in 10,000 displayed some degree of hemolysis and 137 in 10,000 were contaminated. Closed collection was performed at a facility that used a laboratory/hospital information system to keep track of reports and requisition forms, as opposed to manual data management at the facility where open collections were performed. As a result, sample ID/tracking related errors occurred significantly fewer times for specimens obtained via closed collection than for open collection methods. When comparing the use of BD Vacutainer disposable tubes with washable glass vials in the open collection procedure, the disposable tubes fared better for all preanalytical quality variables except under-filling of the collection container. Glass vials were under-filled 203 times in 10,000 while the disposable tubes were under-filled 296 times in 10,000. Nevertheless, these same disposable tubes were only under-filled 18 times in 10,000 when closed collection methods were used.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeMacroscopic observation
    MorphologyMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionData management
    Hospital/laboratory information system
    Manual data management
    Biospecimen AcquisitionMethod of fluid acquisition
    Syringe draw
    Vacuum tube
    Biospecimen AcquisitionType of collection container/solution
    BD Vacutainer tube
    Glass vial