Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis.
Boeynaems JM, De Leener A, Dessars B, Villa-Lobos HR, Aubry JC, Cotton F, Thiry P
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this paper was to compare blood collected and stored in PET tubes, with or without heparin, with blood collected and stored in glass tubes for analysis of clinical chemistry analytes, therapeutic drugs, hormones and trace metals. Chloride, potassium, sodium, magnesium, cholesterol, high density lipoprotein (HDL), cholesterol, triglycerides, C-reactive protein, alpha 1-acid glycoprotein, apolipoprotein B (ApoB), digoxine, thyroxine (T4), free thyroxine (FT4), free triiodothyronine (FT2), follicle stimulating hormone (FSH) luteinizing hormone (LH), prolactin, testosterone, vitamin B12, cortisol, amikacin, lidocaine, salicylate, carcinoembryonic antigen, prostate specific antigen, carbamazepine, gentamicin, phenobarbitol, phenytoin, theophylline, vancomycin, valproate, immunoglobulin (Ig)A, IgG, IgM, gastrin, PTH, zinc, copper, lead, aluminum, arsenic, mercury, manganese, antimony, tin, cadmium and selenium were analyzed.
Summary of Findings
The use of PET tubes instead of glass significantly increased T4, FT2, vitamin B12, prolactin and parathyroid hormone. The use of PET tubes containing heparin, as opposed to glass tubes without heparin, significantly increased prolactin and parathyroid hormone and decreased potassium, gastrin, IgM, and ApoB. However, only potassium, vitmin B12, gastrin and PTH differed by more than 3% between tube types. Storage of blood specimens in the tubes for 24 h at room temperature produced the expected changed in potassium when blood was not separated, but otherwise resulted in only small or inconsistent changes in drug and clinical chemistry analytes. Although some trace metal leaching was observed from the tubes, generally levels were within acceptable levels. However, the use of PET tubes containing heparin was unsuitable for the measurement of antimony.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerPeptideClinical chemistry/auto analyzerGlycoproteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant Lithium heparinNoneBiospecimen Acquisition Type of collection container/solution Becton Dickinson Royal BlueSarstedt syringeVenoject glassVenosafe PETStorage Storage duration 24 h4 hLess than 2 hStorage Storage temperature 4 degrees CRoom temperature