Stability of analytes related to clinical chemistry and bone metabolism in blood specimens after delayed processing.
Zwart SR, Wolf M, Rogers A, Rodgers S, Gillman PL, Hitchcox K, Ericson KL, Smith SM
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effect of storage of whole blood without anticoagulant at room temperature in the dark for up to 24 h on clinical chemistry and bone metabolism analytes including 25-hydroxyvitamin D, alanine aminotrasferase, albumin, alkaline phosphatase, aspartate aminotrasferase, alpha 1 globulin, alpha 2 globulin, beta globulin, calcium, bone-specific alkaline phosphatase, ceruloplasmin, chloride, cholesterol, copper, cortisol, creatinine, ferritin, folate, gamma globulin, homocysteine, iron, methylmalonic acid, osteocalcin, PTH, potassium, PLP, retinol-binding protein, selenium, sodium, total protein, transferrin, transferrin receptors, transthyretin, total antioxidant capacity, triglycerides and zinc.
Summary of Findings
Storage of whole blood at room temperature for 24 h prior to centrifugation and aliquoting serum significantly increased homocysteine (55%, p<0.001), zinc (20%, p<0.001), and PLP (10%, p<0.05), but significantly decreased osteocalcin (-30%, p<0.001), and PTH (-15%, p<0.05). The authors state that none of these changes are likely to be clinically significant when taken as a whole since the means remained in the reference range. However, for individual patients, these changes may result in an altered interpretation of risk.
Biospecimens
FluidBloodFluidSerumPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerGlycoproteinClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerPeptideClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Time at room temperature 2.5 h24 h45 min5 h