Effects of the time intervals between venipuncture and serum preparation for serum peptidome analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Umemura H, Nezu M, Kodera Y, Satoh M, Kimura A, Tomonaga T, Nomura F

Publication: Clin Chim Acta (2009) • Vol 406 • Page 179-80PMID: 19520068View on PubMed

Purpose

The purpose of this paper was to determine if blood specimen processing and handling alters serum peptide profiles.

Conclusion

The biggest effect on peptide peaks was as a result of increasing clotting time. Peaks could be divided into 3 distinct groups based on the effect of increased clotting time on peak intensity: those that decreased rapidly over the first hour and then continued a steady decline (type A), those that increased gradually over the entire 6 h (type B), and those that increased rapidly over the first 30 minutes before slowly declining or remaining constant (type C). The type of peaks observed depended on clotting time and bead type. C8 hydrophobic interaction chromatography (C8) and weak cation exchange (WCX) resulted in mostly type A peaks while immobilized metal affinity chromatography (IMAC-Cu) resulted in mostly type B peaks. No differences in relative peak intensities were observed between samples frozen at -80 degrees C and those frozen in liquid nitrogen. After 2 freeze-thaw cycles, most peaks had a coefficient of variance of less than 20%, however, additional freeze-thaw cycles significantly altered relative peak intensity. In conclusion, freezing temperature and up to 2 freeze-thaw cycles have little effect on peptide peak intensity, but clotting time and bead choice have a significant impact.

Studies (1)

Purpose

The purpose of this study was to determine if clotting time, freezing temperature, freeze-thaw cycling and bead choice for peptide fractionation alter serum peptide profiles by MALDI-TOF mass spectrometry (MS).

Summary of Findings

The biggest effect on peptide peaks was due to increasing clotting time. Peaks could be divided into 3 distinct groups (A, B, and C) based on the effect of increased clotting time on peak intensity. The type of peaks observed depended on clotting time and bead type used. C8 and WCX resulted in mostly type A peaks while IMAC-Cu resulted in mostly type B peaks. No differences in relative peak intensities were observed between samples frozen at -80 degrees C and those frozen in liquid nitrogen. After 2 freeze-thaw cycles, most peaks had a coefficient of variance of less than 20%, however, additional freeze-thaw cycles significantly altered relative peak intensity. In conclusion, freezing temperature and up to 2 freeze-thaw cycles have little effect on peptide peak intensity, but clotting time and bead choice have a significant impact.

  • Biospecimens

    FluidBlood
    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    PeptideMALDI-TOF MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    3 cycles
    4 cycles
    5 cycles
    6 cycles
    7 cycles
    StorageStorage duration
    1 week
    StorageStorage temperature
    -80 degrees C
    Liquid nitrogen
    StorageTime at room temperature
    1 h
    15 min
    2 h
    30 min
    4 h
    6 h
    Analyte Extraction and PurificationAnalyte isolation method
    C8 hydrophobic interaction chromatography
    Immobilized metal affinity chromatography
    Weak cation exchange