Skip to main content

Effects of different fixatives on detection of nucleic acids from paraffin-embedded tissues by in situ hybridization using oligonucleotide probes.

Weiss LM, Chen YY

Publication: J Histochem Cytochem (1991) • Vol 39 • Page 1237-42PMID: 1918942View on PubMed

Purpose

The purpose of this paper was to evaluate the effect of fixative on DNA and mRNA in lymphoid tissue.

Conclusion

Use of the poly d(T) probe for mRNA detection did not correlate with immunoglobulin light chain probe staining for mRNA. Formalin fixation yielded intense in situ hybridization staining when detecting DNA or mRNA. Moderate staining was seen in OmniFix and ethanol-fixed tissue when detecting DNA or mRNA with a poly d(T) probe, but virtually no staining was observed in these tissues when detecting mRNA with light chain probes. Weak staining was observed in B5 and Bouins-fixed tissues with the poly d(T) probe for DNA, while moderate staining was seen using the light chain probe or poly d(T) probe for mRNA.

Studies (1)

Purpose

The purpose of this study was to compare the use of different fixatives for detection of DNA and mRNA in lymphoid tissue through in situ hybridization. After fixation with B5 or Bouins fixative, tissue was transferred to formalin. OmniFix and ethanol fixation were used without subsequent exposure to formalin.

Summary of Findings

Use of the poly d(T) probe for mRNA detection did not correlate with immunoglobulin light chain probe staining for mRNA. Formalin fixation yielded intense in situ hybridization staining when detecting DNA or mRNA. Moderate staining was seen in OmniFix and ethanol-fixed tissue when detecting DNA or mRNA with a poly d(T) probe, but virtually no staining was observed in these tissues when detecting mRNA with light chain probes. Weak staining was observed in B5 and Bouins-fixed tissues with the poly d(T) probe for DNA, while moderate staining was seen using the light chain probe or poly d(T) probe for mRNA. Finally, nuclear staining was predominant with the poly d(T) probe for mRNA while cytoplasmic staining was predominant with the light chain probes.

  • Biospecimens

    TissueLymph Node
    TissueSpleen
  • Preservation Types

    FormalinEthanolOther Preservative
  • Diagnoses

    NeoplasticBenign
    NeoplasticLeukemia
    NeoplasticLymphoma
    NeoplasticOther
  • Platforms

    DNAIn situ hybridization
    RNAIn situ hybridization
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    B-5 fixative
    Bouin's fixative
    Ethanol
    Formalin (buffered)
    Omnifix
    In situ hybridization SpecificType of probe
    Immunoglobulin light chain
    Oligonucleotide poly d(T)