Effects of blood-collection systems and tubes on hematologic, chemical, and coagulation tests and on plasma hemoglobin.
Almagor M, Lavid-Levy O
Purpose
The purpose of this paper was to determine the effects of blood collection systems on hematological and chemical analytes.
Conclusion
Use of the Greiner blood collection system resulted in a nonlinear blood flow and an increase in serum magnesium (Mg), plasma hemoglobin and prothrombin time when compared to the Becton Dickinson (BD) system. The increased serum Mg is believed to be due to optical interference by hemoglobin and the authors suggest measurement of Mg by ion-selective electrode may be necessary. However, despite the hemolysis all test results remained within the normal range.
Studies (1)
Purpose
The purpose of this paper was to compare the use of BD Vacutainer tubes and the Greiner blood collection system when analyzing sodium, potassium, aspartate aminotransferase, alanine aminotransferase amylase, alkaline phosphatase, lactate dehydrogenase, bilirubin, high density lipoprotein (HDL)-cholesterol, magnesium, calcium, differential blood count, activated partial thromboplastin time, prothrombin time, fibrinogen, and hemoglobin.
Summary of Findings
Use of the Greiner blood collection system resulted in a nonlinear blood flow and an increase in serum Mg (2.4%), plasma hemoglobin (31%) and prothrombin time (8%). The increased serum Mg is believed to be due to optical interference by hemoglobin and the authors suggest measurement of Mg by ion-selective electrode may be necessary. However, despite the hemolysis all test results remained within the normal range.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
ProteinClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerCell count/volumeHematology/ auto analyzerProteinSpectrophotometryMorphologyHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Becton Dickinson VacutainerGreiner Vacuette