Skip to main content

Autolysis is a potential source of false aneuploid peaks in flow cytometric DNA histograms.

Alanen KA, Joensuu H, Klemi PJ

Publication: Cytometry (1989) • Vol 10 • Page 417-25PMID: 2766888View on PubMed

Purpose

The purpose of this paper was to determine the effects of tissue type, sampling method and storage on DNA autolysis.

Conclusion

DNA autolysis proceeded rapidly after death in pancreatic specimens where false aneuploid peaks (second G1 peak) were already present after a 10h postmortem interval (PMI) in some formalin fixed paraffin embedded (FFPE) specimens. DNA autolysis occurred more slowly in spleen and thyroid specimens where most were unchanged after a 10 h PMI. Liver specimens showed more rapid DNA autolysis than the spleen and thyroid, but were much better preserved after a 10 h PMI than the pancreas. Intriguingly, false aneuploid peaks occurred more often in fine needle aspiration biopsy (FNAB) than FFPE specimens from spleen, thyroid or liver, but less often in FNAB than FFPE pancreatic specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of tissue type and storage at 4 degrees C or room temperature, and specimen collection method on DNA autolysis. All specimens underwent a postmortem interval of 3-33 h prior to excision of the tissue which was subsequently stored at 4 degrees C or room temperature. FNAB specimens were stored in ethanol while tissue biopsy specimens were fixed in formalin and embedded in paraffin.

Summary of Findings

With storage at 4 degrees C or room temperature, a shoulder appeared on the right side of the G1 peak in some specimens by 10 h postmortem indicating DNA autolysis. Postmortem DNA autolysis proceeded the most rapidly in pancreatic specimens where false aneuploid peaks were already present after a 10 h PMI in some FFPE specimens. DNA autolysis occurred more slowly in spleen and thyroid specimens where most were unchanged after a PMI of 10 h. Liver specimens showed more rapid DNA autolysis than the spleen and thyroid, but were much better preserved after a 10 h PMI than the pancreas. The DNA indices of the false aneuploid peaks varied between 1.09-1.54 with averages of 1.17 in the FNAB group and 1.30 in the FFPE group. Intriguingly, false aneuploid peaks occurred more often in spleen, thyroid, and liver FNAB specimens compared to FFPE specimens, but less often in pancreatic FNAB specimens compared to FFPE specimens.

  • Biospecimens

    TissueLiver
    TissueThyroid Gland
    TissueSpleen
    TissuePancreas
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Cardiovascular Disease
    Autopsy
    Pneumonia/Respiratory Infection
    NeoplasticOther
  • Platforms

    DNAFlow cytometry
    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPostmortem interval
    14 h
    22 h
    3-10 h
    33 h
    Biospecimen AcquisitionBiospecimen location
    Liver
    Pancreas
    Spleen
    Thyroid
    Biospecimen AcquisitionMethod of tissue acquisition
    Biopsy
    Fine needle aspiration
    Biospecimen PreservationType of fixation/preservation
    None (fresh)
    Refrigeration
    StorageStorage duration
    19-38 h
    3-10 h
    46-70 h
    8 days
    StorageTime at room temperature
    12 h
    120 h
    132 h
    24 h
    3 h
    30 h
    36 h
    48 h
    6 h
    9 h
    93 h