Skip to main content

Surgical specimen can be replaced by core samples in assessment of ER, PR and HER-2 for invasive breast cancer.

Sutela A, Vanninen R, Sudah M, Berg M, Kiviniemi V, Rummukainen J, Kataja V, Kärjä V

Publication: Acta Oncol (2008) • Vol 47 • Page 38-46PMID: 17851859View on PubMed

Purpose

The purpose of this paper was to compare stereotactic core needle biopsies (SCNB) with surgical specimens for assessment of estrogen (ER), progesterone (PR) and human epidermal growth-factor (HER-2) receptors in breast carcinomas.

Conclusion

Concordance between immunohistochemical (IHC) staining of surgical specimens and SCNB was observed in 83% of cases for ER, and 88% of cases for PR and HER-2, and 93% of cases if HER-2 in situ hybridization (ISH) was also performed. The discordant specimens most often occurred due to false negative results in surgical specimens. The center and margins of the tumor were concordant 100% of the time for ER, but only 85% of the time for PR and HER-2. The use of three core specimens for IHC staining allowed for 95% sensitivity for ER, and 92% for PR and HER-2, however, the sensitivity increased to 100% if HER-2 ISH was also performed. The addition of further specimens did not increase ER sensitivity, but did increase sensitivity of PR to 100%. In conclusion, SCNB were more sensitive than surgical specimens for ER, PR, and HER-2 staining, but it was necessary to analyze multiple SCNB.

Studies (1)

Purpose

The purpose of this study was to compare IHC staining of ER, PR and HER-2 in SCNB and surgical specimens from breast carcinomas. SCNB from the tumor center versus 2 mm away were also compared.

Summary of Findings

Concordance between IHC staining of surgical specimens and SCNB was observed in 83% of cases for ER, and 88% of cases for PR and HER-2, and 93% of cases if HER-2 ISH was also performed. The false negative rate from surgical specimens was 14% for ER, 15% for PR and 7% for HER-2 (when ISH was included). In contrast, false negatives in SCNB did not occur for PR and HER-2 (with ISH) and occurred in only 6% of specimens for ER. The center and margins of the tumor were concordant 100% of the time for ER but only 85% of the time for PR and HER-2. The use of three core specimens for IHC staining allowed for 95% sensitivity for ER, and 92% for PR and HER-2, however, the sensitivity increased to 100% for HER-2 if ISH was also used. The addition of further specimens did not increase ER sensitivity, but did increase sensitivity of PR to 100%. In conclusion, SCNB were more sensitive than surgical specimens for ER, PR, and HER-2 staining, but it was necessary to analyze multiple SCNB.

  • Biospecimens

    TissueBreast
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    ProteinImmunohistochemistry
    DNAIn situ hybridization
    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of tissue acquisition
    Core needle biopsy
    Surgical resection
    Biospecimen Aliquots and ComponentsBiospecimen heterogeneity
    Biospecimen core
    Biospecimen periphery
    In situ hybridization SpecificTargeted nucleic acid
    Human epidermal growth-factor receptor
    Immunohistochemistry SpecificTargeted peptide/protein
    Estrogen receptor
    Human epidermal growth-factor receptor
    Progesterone receptor