Quality improvement by standardization of procurement and processing of thyroid fine-needle aspirates in the absence of on-site cytological evaluation.
Sidiropoulos N, Dumont LJ, Golding AC, Quinlisk FL, Gonzalez JL, Padmanabhan V
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of standardizing TN FNA collection and preparation methods on specimen quality.
Summary of Findings
Prestandardization methods included collection by multiple physicians, variable use of ultrasound guidance, different needle gauges, and between 2 and 25 air-dried and/or fixed smears per FNA, generated by multiple individuals. Poststandardization methods included collection by one physician, use of ultrasound guidance, a 25-guage needle, four passes resulting in 4 smears (2 air-dried and 2 fixed) prepared by a single nurse and additional material for BD SurePath liquid-based preparation, cell block, and hematoxylin and eosin analysis. While methods were not analyzed individually, specimens categorized as having satisfactory quality increased significantly from 67% to 89% (p<0.0001) after all standardized collection and preparation methods were implemented.
Biospecimens
CellThyroid GlandPreservation Types
Other PreservativeDiagnoses
NeoplasticBenignNeoplasticCarcinomaNeoplasticLymphomaPlatforms
MorphologyLight microscopyMorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of tissue acquisition Fine needle aspirationUltrasound-guided fine needle aspirationBiospecimen Acquisition Needle gauge 22-2725Biospecimen Aliquots and Components Type of slide Air-driedFixed