A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum.
Saleem S, Mani V, Chadwick MA, Creanor S, Ayling RM
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of blood sampling method, tourniquet time and multiple venepuncture attempts on haemolysis of blood.
Summary of Findings
Of 353 blood specimens sampled 6.5% showed haemolysis. Staff group performing the blood draw, collection method, tourniquet time and number of attempts at venepuncture each appeared to be univariatly associated with haemolysis. However, after logistic regression analysis, only tourniquet time of greater than 1 minute was significantly associated with increased haemolysis with an odds ratio (OR) of 19.5. Specimen transport method had no effect on hemolysis.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Butterfly deviceCannulaNeedleStaff group performing phlebotomy comparedSyringe drawTourniquet times comparedVacuum tubeBiospecimen Aliquots and Components Aliquot sequential collection First venipuncture attemptMultiple venipuncture attemptsStorage Within hospital transportation method Hand-deliveredPneumatic tube system