SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.
Traum AZ, Wells MP, Aivado M, Libermann TA, Ramoni MF, Schachter AD
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effect of storage duration at 4 degrees C prior to deep freezing at -80 degrees C on SELDI-TOF MS analysis of both urine and serum specimens.
Summary of Findings
Storage of urine and serum specimens at 4 degrees C for up to 24 h after sample collection prior to frozen storage at -80 degrees C did not significantly affect SELDI-TOF MS spectra. Use of weak cationic exchange arrays (CM10) and anionic (IMAC30) arrays gave similar results. Concordance between each storage time at 4 degrees C and immediate freezing ranged from 71-95% for serum specimens and 79-97% for urine specimens. A non-significant decrease in concordance was observed for serum specimens after storage at 4 degrees C for 24 h. It should be noted that aliquots were obtained from single blood and urine specimens taken from the same adult volunteer.
Biospecimens
FluidUrineFluidSerumPreservation Types
FrozenDiagnoses
NormalPlatforms
PeptideSELDI-TOF MSProteinSELDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location SerumUrineStorage Storage duration 0 h2 h24 h6 hStorage Storage temperature 4 degrees CSELDI-TOF MS Specific Type of array CM10 (weak cationic exchange)IMAC30 (anionic)
Purpose
Summary of Findings
Biospecimens
FluidUrinePreservation Types
FrozenDiagnoses
NormalPlatforms
PeptideSELDI-TOF MSProteinSELDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components pH 4.55.56.57.5SELDI-TOF MS Specific Type of array CM10H50IMAC30