Skip to main content

Stability of coagulation proteins in frozen plasma.

Woodhams B, Girardot O, Blanco MJ, Colesse G, Gourmelin Y

Publication: Blood Coagul Fibrinolysis (2001) • Vol 12 • Page 229-36PMID: 11460005View on PubMed

Purpose

The purpose of this paper was to determine the effect of frozen storage on the stability of coagulation proteins in normal citrated plasma specimens.

Conclusion

Changes of less than 5% from initial values were observed for all coagulation factors after 6 months of storage at -74 degrees C and after 3 months of storage at -24 degrees C. Coagulation factors were not affected by aliquot size for specimens stored at -74 degrees C, but prothrombin time (PT), activated partial thromboplastin time (aPTT) and factor V were less stable at -24 degrees C in 5 ml tubes than in 1 ml tubes. Freezing the specimens at -74 prior to storage at -24 degrees C versus freezing and storage at -24 degrees C had no effect on coagulation factors. The authors conclude that specimens should be stored in 1 ml tubes and can be stored safely for up to 3 months at -24 degrees C or 6 months at -74 degrees C.

Studies (1)

Purpose

The purpose of this study was to determine the effects of frozen storage temperature, duration, and aliquot size on the stability of coagulation proteins in normal plasma specimens.

Summary of Findings

Variations of less than 5% were observed for at least 6 months in all analytes stored at -74 degrees C and for 3 months if storage was at -24 degrees C. In specimens stored at -74 degrees C, PT, thrombin time (TT), fibrinogen, factor V, factor X, protein C and von Willebrand factor (vWF) varied by less than 5% for at least a year and aPTT, factor II, factor VII, factor IX, factor XII, antithrombin, plasminogen and D-dimer varied by less than 5% after the full two years. In specimens stored at -24 degrees C, variation of fibrinogen, protein C and vWF was less than 5% for at least a year and antithrombin, plasminogen and D-dimer variation remained under 5% for the full two years. No effect of freezing at -74 degrees C prior to storage at -24 degrees C versus freezing and storage at -24 degrees C on analyte stability was found. Freezing in one ml versus five ml tubes increased stability of PT, aPTT and factor V when stored at -24 degrees C, but had no effect on other analytes or when specimens were stored at -74 degrees C.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    MorphologyHematology/ auto analyzer
    ProteinHematology/ auto analyzer
    PeptideHematology/ auto analyzer
    GlycoproteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot size/volume
    1 ml
    5 ml
    Biospecimen PreservationCooling or freezing method/ rate
    Freezing at -24 degrees C
    Freezing at -74 degrees C
    StorageStorage duration
    0 weeks
    1 month
    10 months
    11 months
    12 months
    13 months
    14 months
    15 months
    16 months
    17 months
    18 months
    19 months
    2 months
    2 weeks
    20 months
    21 months
    22 months
    23 months
    24 months
    3 months
    4 months
    5 months
    6 months
    7 months
    8 months
    9 months
    StorageStorage temperature
    -24 degrees C
    -74 degrees C