Skip to main content

Preanalytical variables in measurement of free (ionized) calcium in lithium heparin-containing blood collection tubes.

Haverstick DM, Brill LB 2nd, Scott MG, Bruns DE

Publication: Clin Chim Acta (2009) • Vol 403 • Page 102-4PMID: 19361462View on PubMed

Purpose

The purpose of this paper was to evaluate the effects of collection container and delayed processing on free calcium (iCa) in plasma.

Conclusion

iCa in plasma collected in lithium-heparin PST tubes was not affected by draw order, lot number, or storage, but was lower than when specimens were collected in electrolyte-balanced heparin syringes.

Studies (3)

Purpose

The purpose of this study was to determine the effect of collection of blood in lithium-heparin BD Vacutainer PST or electrolyte-balanced heparin syringes on plasma free calcium (iCa). Prior to the first measurement tubes were transported at ambient temperatures and syringes were transported on ice.

Summary of Findings

iCa was an average of 0.08 mmol/L lower in plasma collected in lithium heparin tubes than in syringes.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Electrolyte-balanced heparin syringe
    Lithium-heparin BD Vacutainer PST
    StorageStorage temperature
    Ambient temperature
    Ice