Effect of shipment, storage, anticoagulant, and cell separation on lymphocyte proliferation assays for human immunodeficiency virus-infected patients.

Weinberg A, Betensky RA, Zhang L, Ray G

Publication: Clin Diagn Lab Immunol (1998) • Vol 5 • Page 804-7PMID: 9801338View on PubMed

Purpose

The purpose of this paper was to evaluate the effects of anticoagulant, cell separation, transportation, storage and Human immunodeficiency virus (HIV) status on lymphocyte proliferation in response to 4 viral stimuli.

Conclusion

HIV positive specimens were more likely to undergo lymphocyte proliferation in response to stimulation independent of antigen used. A positive lymphocyte proliferation assay (LPA) result occurred 51% of the time when peripheral blood mononuclear cells (PBMC) were used versus 17% of the time when whole blood was used, regardless of anticoagulant or overnight transportation. Further, the odds of a positive LPA result were higher from fresh specimens than from those shipped overnight. The use of heparin or citrate as anticoagulants increased the odds of positive LPA results compared to use of acid citrate dextrose (ACD). Furthermore, for 3 of 4 antigens, use of citrate tubes increased the odds of positive LPA results when compared with heparin in uninfected controls. For HIV infected patients, heparin and citrate performed similarly. The authors conclude that specimens should be collected in heparin or ACD tubes and separated on site for LPAs.

Studies (1)

Purpose

The purpose of this study was to evaluate the effects of anticoagulant, cell separation, transportation, cryopreservation and HIV status on lymphocyte proliferation in response to 4 viral stimuli.

Summary of Findings

HIV positive specimens were more likely to undergo lymphocyte proliferation in response to stimulation independent of antigen used. A positive LPA result occurred 51% of the time when PBMC were used versus 17% of the time when whole blood was used, regardless of anticoagulant or overnight transportation. Further, the odds of a positive LPA result were higher from fresh specimens than from those shipped overnight. The use of heparin or citrate as anticoagulants increased the odds of positive LPA results compared to use of ACD. Furthermore, for 3 of 4 antigens, use of citrate tubes increased the odds of positive LPA results when compared with heparin in uninfected controls. For HIV infected patients, heparin and citrate performed similarly. The authors conclude that specimens should be collected in heparin or ACD tubes and separated on site for LPAs.

  • Biospecimens

    FluidBlood
    CellBlood
  • Preservation Types

    None (Fresh)Frozen
  • Diagnoses

    AIDS/HIV-related
    Normal
  • Platforms

    Cell count/volumeRadioassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    CMV positive
    CMV unknown
    HIV negative
    HIV positive
    Previous tetanus vaccine
    VZV positive
    Biospecimen AcquisitionAnticoagulant
    Acid-citrate-dextrose
    Citrate
    Heparin
    Biospecimen Aliquots and ComponentsBlood and blood products
    Peripheral blood mononuclear cells
    Whole blood
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageBetween site transportation method
    Mailed
    Not transported
    Radioassay SpecificAntigen
    Candida
    Cytomegalovirus
    Phytohemagglutinin
    Tetanus
    Toxoid antigens
    Varicella-zoster virus