Effect of collection tube type and preanalytical handling on myeloperoxidase concentrations.
Shih J, Datwyler SA, Hsu SC, Matias MS, Pacenti DP, Lueders C, Mueller C, Danne O, Möckel M
Purpose
Conclusion
Studies (3)
Purpose
The purpose of this study was to determine the effects of collection tube type and storage duration prior to centrifugation either in an ice bath or at room temperature on MPO concentration in normal blood specimens.
Summary of Findings
EDTA and citrate plasma tubes gave the lowest concentrations of MPO and were not significantly different. Average MPO concentrations were significantly higher in heparin (10%) and serum specimens (up to 100%) (p<0.001). A spike recovery experiment showed that the higher MPO concentrations were not due to direct anticoagulant interference. MPO concentration was stable when whole blood was kept on ice for 8 hours or at room temperature for 2 hours prior to centrifugation in either EDTA or EDTA plasma preparation tubes. In citrate and lithium heparin tubes, MPO concentrations were only stable when whole blood was kept on ice for 2 hours prior to centrifugation and were not stable when whole blood was stored at room temperature.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
ProteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution K2 EDTAK2 EDTA plasma preparationLithium heparin (glass)Lithium heparin (plastic)Lithium heparin plasma separatorSerum (glass)Serum (plastic)Serum separatorSodium citrateSodium heparinBiospecimen Aliquots and Components Blood and blood products PlasmaSerumBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage duration 0 h2 h8 hStorage Storage temperature 0 degrees CRT
Purpose
The purpose of this study was to determine the effects of storage of plasma or serum at room temperature or at 2-8 degrees C, and freeze/thaw cycling following centrifugation on MPO concentration in normal specimens.
Summary of Findings
Storage of plasma or serum at room temperature for 2 days, at 2-8 degrees C for 8 days, or during up to 3 freeze/thaw cycles only altered MPO concentrations by 7% or less from baseline in any tested tube type with EDTA tubes performing the best.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
ProteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution K2 EDTA plasma preparationLithium heparin plasma separatorSerum separatorBiospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Freeze/thaw cycling 0 cycles1 cycle2 cycles3 cyclesStorage Storage duration 0 d1 d2 d5 d8 dStorage Storage temperature 2-8 degrees CStorage Time at room temperature 0 h24 h3.5 h48 h
Purpose
The purpose of this study was to determine the effects of collection tube type on MPO concentration in specimens collected from patients presenting with chest pain.
Summary of Findings
EDTA and citrate plasma tubes were similar and gave the lowest concentrations of MPO. Lithium heparin and serum samples had average MPO concentrations of between 2.5 and 3 times those levels found in EDTA and citrate tubes.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Cardiovascular DiseasePlatforms
ProteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution CitrateK2 EDTALithium heparin plasma separatorSerum separatorBiospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Storage temperature 2-8 degrees C