Effect of time, temperature and additives on a functional assay of C1 inhibitor.
Nielsen EW, Johansen HT, Straume B, Mollnes TE
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of anticoagulant and storage at 4 or 37 degrees C for up to 24 h on the activity of C1-INH in plasma and serum from normal and HAE patients. Serum specimens were allowed to coagulate for 2 h at room temperature prior to centrifugation. After the allotted storage time, all specimens were stored at -70 degrees C until analysis.
Summary of Findings
C1-INH activity was falsely elevated in heparin treated plasma and falsely depressed in polybrene-EDTA treated plasma. Significantly higher C1-INH activity was observed in serum, EDTA-treated plasma and heparin-treated plasma, then in citrate-treated plasma from healthy volunteers (p=0.0003-0.0025), but not from HAE patients (p=0.055-0.8). Activity of C1-INH decreased by 12-19% after storage of normal plasma (EDTA, heparin, or citrate-treated) or serum for 24 h at 37 degrees C. A decline in C1-INH activity of 5-14% was noted after 24 h at 4 degrees C for normal plasma (EDTA, heparin, or citrate-treated) or serum. The decline in C1-INH activity was far more pronounced in HAE patients after storage at either 37 (48-83%) or 4 degrees C (35-80%) and was also found for polybrene-EDTA-treated plasma. Although a significant effect of storage was found for both healthy volunteers (p=0.039) and HAE patients (0.0002) there was no significant difference between the two temperatures. In conclusion, EDTA-treated plasma or serum were the best choices for measurement of C1-INH activity and C1-INH activity declines with storage at 4 or 37 degrees C.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
FrozenDiagnoses
NormalOther diagnosesPlatforms
ProteinEnzyme assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Hereditary angioedemaBiospecimen Acquisition Anticoagulant EDTAHeparinPolybrene EDTASodium citrateBiospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Storage conditions 0 h24 h6 hStorage Storage temperature -70 degrees C37 degrees C4 degrees C
Purpose
The purpose of this study was to determine the effect of storage of serum at room temperature for up to 5 days on the activity and protein levels of C1-INH from healthy volunteers and HAE patients. After the allotted storage time, all specimens were stored at -70 degrees C until analysis.
Summary of Findings
Storage of pooled serum at room temperature decreased C1-INH activity levels by 15% after 1 day, 20% after 2 days, 24% after 3 days, and 22% after 5 days (p=0.055). While no changes in C1-INH levels in healthy individuals were observed by Western blot after 5 days of storage at room temperature, in HAE patients, the band representing intact C1-INH disappeared and a faint smaller band appeared after 5 days at room temperature. In addition, a new higher molecular weight band appeared both in serum from healthy volunteers and HAE patients. In conclusion, storage of serum at room temperature reduces C1-INH activity, but an observable effect on C1-INH levels by Western blot was only found in HAE patients.
Biospecimens
FluidSerumFluidBloodPreservation Types
FrozenDiagnoses
NormalOther diagnosesPlatforms
ProteinEnzyme assayProteinWestern blotPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Hereditary angioedemaStorage Storage temperature -70 degrees CStorage Time at room temperature 0 days1 day2 days3 days5 days