Comparison of soluble thrombomodulin, von Willebrand factor, tPA/PAI-1 complex, and high-sensitivity CRP concentrations in serum, EDTA plasma, citrated plasma, and acidified citrated plasma (Stabilyte) stored at -70 degrees C for 8-11 years.

Nilsson TK, Boman K, Jansson JH, Thøgersen AM, Berggren M, Broberg A, Granlund A

Publication: Thromb Res (2005) • Vol 116 • Page 249-54PMID: 15935834View on PubMed

Purpose

The purpose of this paper was to find the optimal collection tube for measurement of soluble Thrombomodulin (sTM), von Willebrand Factor (vWF), tissue plasminogen activator/plasminogen activator inhibitor 1 (tPA/PAI-1) complex, and high sensitivity C-Reactive Protein (hsCRP).

Conclusion

Stabilyte (acidic citrate) tubes performed better than sodium citrate tubes for sTM and tPA/PAI-1 complex concentrations and similarly for vWF and hsCRP concentrations. In general, EDTA tubes performed worse than sodium citrate and Stabilyte tubes. Serum tubes also generally performed worse than the other tubes, particularly in sTM and vWF assays. In conclusion, Stabilyte is the best tube choice for biobanks investigating fibrinolytic factors or other aspects of the clotting system.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube type on sTM, vWF, tPA/PAI-1 complex, and hsCRP concentration determination in serum and plasma. All specimens were stored for 8-11 years at -70 degrees C prior to analysis.

Summary of Findings

When plotted against paired citrate specimens, sTM was very unstable in serum and marginally unstable in K3EDTA tubes, but showed increased stability in the more highly acidic Stabilyte tubes. vWF concentrations were similar across tube types, but serum specimens had not been diluted 1:10 indicating a substantial loss of vWF immunoreactivity in serum. While no change in the slopes of tPA/PAI-1 in citrate tubes versus any other tube were observed, the values were lower in specimens collected in Stabilyte tubes than those collected in other tube types. The authors report that results for hsCRP in serum and K3EDTA tubes did not differ from what was expected based on dilution effect. The authors conclude that Stabilyte tubes are the best choice for biobanks investigating fibrinolytic factors or other aspects of the clotting system.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Cardiovascular Disease
  • Platforms

    ProteinELISA
    GlycoproteinELISA
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Buffered acidic citrate
    Potassium EDTA
    Sodium citrate
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    StorageStorage duration
    8-11 years
    StorageStorage temperature
    -70 degrees C