Skip to main content

Effect of specimen collection on routine coagulation assays and D-dimer measurement.

Lippi G, Guidi GC

Publication: Clin Chem (2004) • Vol 50 • Page 2150-2PMID: 15502084View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection of multiple blood specimens from one venipuncture or of a subsequent venipuncture immediately following the first one on standard coagulation analysis and D-dimer assays.

Conclusion

No statistically significant differences in prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, or D-dimer measurement were seen between the first collection (obtained immediately after an initial venipuncture), the second collection (obtained immediately after the first collection), and the third collection (obtained immediately after a second venipuncture) for 28 individuals when collection was performed by a single phlebotomist. Although some procedures recommend discarding the first sample collected for coagulation analysis, the authors conclude this is not necessary if a standard blood collection procedure is followed, minimizing preanalytical variables.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection of multiple blood specimens from one venipuncture or of subsequent venipunctures immediately following the first one on PT, aPTT, fibrinogen, and D-dimer measurement. All patients were taking an oral anticoagulant at the time of blood draw. Specimens were stored at -70 degrees C prior to analysis.

Summary of Findings

No statistically significant differences in PT, aPTT, fibrinogen, or D-dimer measurement were seen between the first collection (obtained immediately after an initial venipuncture), the second collection (obtained immediately after the first collection), and the third collection (obtained immediately after a second venipuncture) for 28 individuals when collection was performed by a single phlebotomist.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    GlycoproteinHematology/ auto analyzer
    PeptideHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Arm
    Left and right sides compared
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    2nd collection
    3rd collection