Avoidance of contamination in element analysis of serum samples.

Lakomaa EL, Mussalo-Rauhamaa H, Salmela S

Publication: J Trace Elem Electrolytes Health Dis (1988) • Vol 2 • Page 37-41PMID: 2980791View on PubMed

Purpose

The purpose of this paper was to determine the effects of long term storage of serum at -18 degrees C on copper, zinc, selenium, sodium, and chloride concentrations after repeated freeze-thaw cycles.

Conclusion

There were no statistically significant changes in copper zinc, or selenium concentrations after storing serum for over 4 years at -18 degrees C. There was also no change in sodium or chloride concentration over 29 months, which the authors believe indicates no water loss.

Studies (1)

Purpose

The purpose of this study was to determine the effects of long term storage of serum at -18 degrees C on copper, zinc, selenium, sodium, and chloride concentrations after repeated freeze-thaw cycles. Polyethylene storage tubes were prewashed with 1% Deconex overnight, and then a 1+1 solution of suprapure HNO3.

Summary of Findings

There were no statistically significant changes in copper zinc, or selenium concentrations after storing serum for over 4 years at -18 degrees C. There was also no change in sodium or chloride concentration over 29 months, which the authors believe indicates no water loss.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalAtomic absorption spectroscopy
    Electrolyte/MetalInstrumental neutron activation analysis
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    3 cycles
    4 cycles
    StorageStorage duration
    0 months
    19 months
    29 months
    34 months
    43 months
    46 months
    51 months
    StorageStorage temperature
    -18 degrees C