Stability of plasma homocysteine, S-adenosylmethionine, and S-adenosylhomocysteine in EDTA, acidic citrate, and Primavette collection tubes.
Hübner U, Schorr H, Eckert R, Geisel J, Herrmann W
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the stability of Hcy, SAH, and SAM after storage of whole blood specimens at room temperature or 4 degrees C for up to 24 hours in either EDTA, acidic citrate or Primavette tubes. Specimens were obtained from both healthy volunteers and renal patients.
Summary of Findings
Hcy was stabilized in acidic citrate tubes and, to an even greater degree, in Primavette tubes at room temperature, presumably due to blocked SAH hydrolase activity. In EDTA tubes, Hcy showed a 1.8-fold increase after 24 hours at room temperature. SAH increased in all three tube types stored at room temperature, but SAM decreased in EDTA tubes, and to a lesser extent in acidic citrate tubes, SAM remained stable in Primavette tubes. In EDTA tubes, the increase in Hcy seen after storage at room temperature was even greater for renal patients than for healthy volunteers (p<0.001). Storage at 4 degrees C attenuated all changes in Hcy, SAH and SAM. Baseline values of Hcy were 11% lower for HPLC than FPIA for Primavette specimens but no other differences were observed between the two methods.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
NormalOther diagnosesPlatforms
Small moleculeHPLCSmall moleculeImmunoassaySmall moleculeLC-MS or LC-MS/MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition HealthyRenal conditionBiospecimen Acquisition Anticoagulant Buffered acidic citrateEDTAPrimavetteBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage duration 0 h2 h24 h6 hStorage Storage temperature 4 degrees CRoom temperatureHPLC Specific Technology platform Fluorescence polarization immunoassay