The purpose of this paper was to determine the effects of storage of serum under different conditions on specimen evaporation and the detection of 10 clinical chemistry analytes.

Conclusion

Storage of specimens for 4 h at either 4 degrees C or room temperature resulted in increased concentrations of most analytes which the authors attribute to specimen evaporation. Specimens stored uncovered at ambient temperatures had larger changes in analyte levels and weight then those stored in airtight containers in the refrigerator. Bilirubin levels decreased with light exposure, but were stabilized by storage in the dark. In conclusion, for accurate quantification, specimens should be processed immediately but the effects of any delay may be minimized by storage in an airtight opaque container in the refrigerator.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage of serum for 4 h covered or uncovered, at room temperature or in the refrigerator on specimen weight and on the concentrations of 10 clinical chemistry analytes. Analytes studied include lactate dehydrogenase, alkaline phosphatase, bilirubin, creatinine, uric acid, cholesterol, inorganic phosphorous, calcium, albumin and total protein.

Summary of Findings

Storage for 4 h at 4 degrees C or room temperature led to changes in specimen weight and in the detected levels of many analytes. Specimens stored in amber glass in the refrigerator with an airtight lid consistently had a slight change in inorganic phosphorous levels and had a 4.26% weight loss. Storage of specimens uncovered in the refrigerator, resulted in increased uric acid, cholesterol, inorganic phosphorous, calcium, albumin, lactate dehydrogenase and protein levels as well as a 6.6% decrease in specimen weight. Storage for 4 hours in ambient conditions, generally led to larger increases then what was observed in refrigerated specimens, regardless of the container, with consistent increases also observed for creatinine and alkaline phosphatase and a corresponding 9.3% decrease in specimen volume. A slight decrease in bilirubin was also observed in these specimens and was most likely due to light exposure. Storing specimens with an opaque, but not airtight cover at ambient temperatures led to larger changes in analytes in one experiment, but smaller changes in a replicate experiment where a 2.6% decrease in specimen weight was observed. The authors conclude that storage of specimens led to specimen evaporation which was accelerated in specimens stored at room temperature or uncovered. Further, accurate quantification of bilirubin required storage of specimens in the dark.
  • Biospecimens

    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    ProteinClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage conditions
    Air-tight
    Covered
    Dark
    Light
    Uncovered
    StorageStorage duration
    4 h
    StorageStorage temperature
    4 degrees C
    Room temperature