Skip to main content

Effect of pre-analytical variables on glycohemoglobin measurements in routine clinical care.

Camargo JL, Felisberto M, Gross JL

Publication: Clin Biochem (2004) • Vol 37 • Page 836-9PMID: 15329325View on PubMed

Purpose

To analyze the effects of storage conditions on the removal and quantification of the labile hemoglobin A1C (A1C) from diabetic blood specimens.

Conclusion

Treatment of red blood cells with saline at 37 degrees C for 6 h or incubation of whole blood at 37 degrees C for 6 h were the most effective ways to eliminate labile A1C. A1C in whole blood was stable for 100 days at -80 degrees C, 10 days at 4 degrees C and less than 1 day at -20 degrees C.

Studies (2)

Purpose

The purpose of this study was to find the optimal method for removal of labile A1C from diabetic blood specimens.

Summary of Findings

Removal of labile A1C from blood was most effective with either a 6 h saline treatment at 37 degrees C of red blood cells or incubation of whole blood for 6 h at 37 degrees C. Incubation of whole blood or treatment of red blood cells with saline for 3 hr at 37 degrees C did not significantly alter total A1C levels, but the increased A1C was clinically relevant. Hemolysis at pH 5.0 was also significantly less effective at removal of labile A1C (p<0.001).

  • Biospecimens

    FluidBlood
    CellRed Blood Cells
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Diabetes Type 2
    Diabetes Type 1
  • Platforms

    ProteinHPLC
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    EDTA
    Biospecimen Aliquots and ComponentsBlood and blood products
    Red blood cells
    Whole blood
    Analyte Extraction and PurificationAnalyte purification
    Hemolysis at pH 5.0
    Incubation at 37 degrees C
    Saline treatment at 37 degrees C
    Analyte Extraction and PurificationIncubation duration/condition
    3 h
    6 h