Skip to main content

Real-time quantitative assay for routine testing of HCV RNA in formalin-fixed, paraffin-embedded liver samples.

Gruppioni E, Vasuri F, Fiorentino M, Capizzi E, Altimari A, Pirini MG, Grazi GL, Malvi D, Grigioni WF, D'Errico-Grigioni A

Publication: Diagn Mol Pathol (2009) • Vol 18 • Page 232-8PMID: 19861893View on PubMed

Purpose

The purpose of this paper was to validate real-time PCR amplification of hepatitis C virus (HCV) from formalin fixed paraffin embedded (FFPE) liver specimens for use in the diagnosis of hepatitis C.

Conclusion

HCV was detected by real-time PCR in 79% of the 215 cases studied, including 8 cases found to be negative by immunohistochemistry (IHC). No cases were found to be positive by IHC and negative by real-time PCR. Real-time PCR results correlated well with IHC results, serum viral load, and several liver function tests. In conclusion real-time PCR of FFPE is a sensitive method by which to detect HCV infection.

Studies (1)

Purpose

The purpose of this study was to compare real-time PCR of FFPE liver specimens with IHC, serum viral load, and liver function test results for the diagnosis of hepatitis C.

Summary of Findings

HCV was detected by real-time PCR in 79% of the 215 cases studied including 8 cases found to be negative by IHC and in one case that had been archived for 7 years. No cases were found to be positive by IHC and negative by real-time PCR, indicating that real-time PCR is more sensitive then IHC for HCV detection. Strong correlations were observed between positive real-time PCR results and IHC staining (p<0.001), serum viral load (p<0.001), gamma-glutamyl transpeptidase activity (p=0.012), aspartate aminotransferase activity (AST) (p=0.001), and AST alanine aminotransferase ratio (p=0.029). In contrast, IHC results only correlated with AST activity (p=0.025) and serum viral load did not correlate significantly with any other serological marker. When HCV infection was grouped based on percentage of hepatocytes positive for HCV by IHC, real-time PCR (p<0.001), serum viral load (p=0.001) and AST levels (p=0.014) were significantly different among the groups. In conclusion, real-time PCR was found to be more sensitive then IHC at detecting HCV in FFPE specimens and correlated with IHC results, serum viral load and several liver function tests.

  • Biospecimens

    TissueLiver
    FluidSerum
  • Preservation Types

    Formalin
  • Diagnoses

    Hepatitis
  • Platforms

    RNAReal-time qRT-PCR
    ProteinImmunohistochemistry
    ProteinClinical chemistry/auto analyzer
    ProteinEnzyme assay
    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionBiospecimen location
    Liver
    Serum
    Real-time qRT-PCR SpecificTargeted nucleic acid
    GUS
    HCV
    Real-time qRT-PCR SpecificTechnology platform
    Immunohistochemistry
    Liver function tests
    Serum viral load