Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies.
Clark S, Youngman LD, Palmer A, Parish S, Peto R, Collins R
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to measure the concentrations and determine the stability of albumin, apoA1, apoB, total protein, triglycerides, cholesterol, HDL, LDL, ALT, creatinine, CK, GGT, and AST after delayed separation of whole blood and storage at either 21 or 4 degrees C. Blood was collected into potassium EDTA tubes with aprotinin. All plasma specimens were stored at -80 degrees C once separated and analyzed together in one batch.
Summary of Findings
Changes in concentration of less than 4% were observed for albumin, apoA1, apoB, total protein, triglycerides, cholesterol, and HDL when whole blood was stored at 21 degrees C or 4 degrees C. LDL concentration changed by less than 7% when stored at either temperature. On the other hand, ALT, creatinine, CK, and GGT concentrations changed upwards of 10% after storing whole blood for 7 days at 21 degrees C. However, these analytes showed less than 4% change after storage at 4 degrees C for up to 7 days. AST was the only analyte measured that showed marked differences in concentration after storage of whole blood at either temperature.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
LipidClinical chemistry/auto analyzerLipoproteinClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage duration 0 d1 d2 d3 d4 d7 dStorage Storage temperature 21 degrees C4 degrees C