Skip to main content

Effects of formalin, methacarn, and fineFIX fixatives on RNA preservation.

Dotti I, Bonin S, Basili G, Nardon E, Balani A, Siracusano S, Zanconati F, Palmisano S, De Manzini N, Stanta G

Publication: Diagn Mol Pathol (2010) • Vol 19 • Page 112-22PMID: 20502189View on PubMed

Purpose

The purpose of this paper was to compare the preservation of RNA between different tissue specimens fixed in formalin, methacarn, or FineFIX with fresh frozen controls.

Conclusion

Total RNA amount recovered was significantly lower in formalin-fixed tissues than in tissues fixed in methacarn or FineFIX. rRNA was degraded in all fixed tissues while mRNA amount was preserved in methacarn-fixed specimens, but lower in formalin and FineFIX-fixed specimens when compared to fresh frozen controls. However, when RT-PCR was used to assess mRNA integrity, specimens fixed in FineFIX showed successful amplification of 438 bp amplicons, similar to methacarn-fixed specimens, whereas only amplicons up to 200 bp long were amplified from formalin-fixed tissue. These results suggest that both methacarn and FineFIX fixation are more conservative methods than formalin fixation.

Studies (1)

Purpose

The purpose of this study was to compare the amount and integrity of RNA extracted from fresh frozen tissue with that from tissues fixed in formalin, methacarn, or FineFIX. FineFIX-fixed specimens were preserved and processed using a microwave processor, while formalin and methacarn-fixed specimens were processed conventionally.

Summary of Findings

Total RNA amount recovered was on average 50% lower in formalin-fixed tissues than in tissues fixed in methacarn or FineFIX or fresh frozen tissues. rRNA was degraded in all fixed tissues with RNA integrity number (RIN) values ranging from 2.3 to 2.6 compared with an RIN of 7.4 for fresh frozen tissue where RIN values >6 were defined as good quality RNA. mRNA expression levels, as detected by real time qRT-PCR, were preserved in methacarn-fixed specimens, but lower in formalin and FineFIX-fixed specimens when compared to fresh frozen controls. However, when RT-PCR was used to assess mRNA integrity, specimens fixed in FineFIX showed successful amplification of 438 bp amplicons, similar to methacarn-fixed specimens, whereas only amplicons up to 200 bp long were amplified from formalin-fixed tissue.

  • Biospecimens

    TissueColorectal
    TissueGall Bladder
    TissueBreast
    TissueLung
    TissueProstate
    TissueKidney
  • Preservation Types

    FormalinFrozenOther Preservative
  • Diagnoses

    Not specified
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
    RNAElectrophoresis
    RNANorthern blot
    RNAReal-time qRT-PCR
    RNART-PCR
    RNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationEmbedding medium
    Conventional paraffin embedding
    Microwave-assisted paraffin embedding
    Biospecimen PreservationType of fixation/preservation
    FineFIX
    Formalin (buffered)
    Methacarn
    Snap frozen
    Analyte Extraction and PurificationAnalyte isolation method
    Proteinase K-based method
    TRIzol reagent
    RT-PCR SpecificLength of gene fragment
    177 bp
    291 bp
    438 bp
    651 bp
    77 bp
    RT-PCR SpecificTargeted nucleic acid
    ACTB
    Real-time qRT-PCR SpecificTargeted nucleic acid
    ACTB
    ATP5B
    HPRT