Skip to main content

Enumeration of human lymphocyte subsets by monoclonal antibodies and flow cytometry: a comparative study using whole blood or mononuclear cells separated by density gradient centrifugation.

De Paoli P, Reitano M, Battistin S, Castiglia C, Santini G

Publication: J Immunol Methods (1984) • Vol 72 • Page 349-53PMID: 6332151View on PubMed

Purpose

The purpose of this paper was to evaluate the effects of two mononuclear cell separation techniques on lymphocyte subpopulations.

Conclusion

While neither T subsets nor B lymphocytes showed significant changes between whole blood, Ficoll-Paque, or Percoll separation, large granular lymphocytes, recognized by both the Leu7 and Leu11 antibodies, were significantly increased in separated cells. Furthermore, selective enrichment of some subsets was observed at different levels for each separation method. The authors conclude that analysis of peripheral blood lymphocytes should be carried out using various separation techniques to account for these differences.

Studies (1)

Purpose

Monoclonal antibodies recognizing T or B lymphocytes, or natural killer cells were used to quantitate lymphocyte subpopulations in whole blood or after cell separation via density gradient centrifugation.

Summary of Findings

Cell separation resulted in significant changes in the percentage of large granular lymphocytes while T and B lymphocyte subpopulations did not change. Differences between the two separation methods were also observed. Natural killer cells (Leu7+ Leu11+) were selectively enriched at the Percoll interface I, while OKT8+, Leu7+, Leu11- cells were enriched at the bottom of the Ficoll tubes. Interestingly, the results suggest the Leu7+ subpopulation of lymphocytes can be further categorized based on reactivity with Leu11, natural killer activity, and density.

  • Biospecimens

    FluidBlood
    CellWhite Cells
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeFlow cytometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Lymphocyte
    Whole blood
    Analyte Extraction and PurificationAnalyte isolation method
    Ficoll-Paque separation
    Percoll separation
    Flow cytometry SpecificTargeted peptide/protein
    B1
    HLA-DR
    IgD
    Leu11
    Leu7
    OKT3
    OKT4
    OKT8