Comparative biomarker expression and RNA integrity in biospecimens derived from radical retropubic and robot-assisted laparoscopic prostatectomies.
Ricciardelli C, Bianco-Miotto T, Jindal S, Dodd TJ, Cohen PA, Marshall VR, Sutherland PD, Samaratunga H, Kench JG, Dong Y, Wang H, Clements JA, Risbridger GP, Sutherland RL, Tilley WD, Horsfall DJ
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to observe any morphological differences between RALP- and RRP-derived tissue specimens and to determine if there were any changes in protein expression of 14 candidate biomarkers between the two specimen cohorts. Highlighted biomarkers examined included CK8/18, CKHMW, KLK-2, KLK-4, and KLK-14, as well as intersite controls androgen receptor (AR) and prostate-specific antigen (PSA). Notably, the type of fixative used to preserve the paraffin-embedded specimens used in these sample cohorts was not specified.
Summary of Findings
No differences in prostate tissue morphology were observed in H&E-stained sections of tissue microarray (TMA) containing samples from 22 RRP and 23 RALP procedures. While immunohistochemistry showed no statistically significant changes in expression of AR, ghrelin, Ki67, PCNA, VEGF-C, PAR2, YB1, p63, versican, or chondroitin 0-sulfate in RALP tissue as compared with RRP tissue, PSA, CK8/18, CKHMW, and KLK4 had increased expression and KLK2 and KLK14 had decreased expression. For AR, the percentage of immunopositive nuclei were compared while for all other biomarkers, the intensity of immunostaining was compared. While AR immunostaining exhibited a modest difference in the percentage of immunopositive nuclei among two of three participating sites, effects attributable to RALP versus RRP were not observed.
Biospecimens
TissueProstatePreservation Types
Other PreservativeDiagnoses
NeoplasticCarcinomaPlatforms
MorphologyH-and-E microscopyProteinTissue microarrayProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Biomarker level 5.7 ng/ml PSA8.5 ng/ml PSAPreaquisition Warm ischemia time 1.25-1.75 h30-40 minBiospecimen Acquisition Method of tissue acquisition Laproscopic surgeryOpen surgeryImmunohistochemistry Specific Targeted peptide/protein ARC-0-SCK8/18CKHMWGhrelinKLK-14KLK-2KLK-4Ki67PAR2PCNAPSAVEGF-CVersicanYB1p63
Purpose
RNA quality was assessed using 5 RALP and 5 RRP specimens. Gene expression data for AR, PSA, KLK-2, KLK-4, and hypoxia-induced factor HIF1A was collected to determine any differences between the RALP and RRP tissue specimens.
Summary of Findings
High-quality RNA was found in both RALP and RRP tissue using the Agilent bioanalyzer, and the RNA integrity number values were not significantly different. Additionally, no gene expression differences were observed between RALP and RRP tissue for the five genes tested.
Biospecimens
TissueProstatePreservation Types
FrozenDiagnoses
NeoplasticCarcinomaPlatforms
RNAAutomated electrophoresis/BioanalyzerRNAReal-time qRT-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Warm ischemia time 0.5-1.75 h30-40 minBiospecimen Acquisition Method of tissue acquisition Laproscopic surgeryOpen surgeryReal-time qRT-PCR Specific Targeted nucleic acid ARHIF1AKLK-2KLK-4PSA