Collection of human genomic DNA from buccal cells for genetics studies: comparison between cytobrush, mouthwash, and treated card.
Mulot C, Stücker I, Clavel J, Beaune P, Loriot MA
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effect of storage duration (2-7 d) and biospecimen collection method (mouthwash, cytobrush and treated cards) on buccal cell DNA yield and quality.
Summary of Findings
The mouthwash and cytobrush methods allowed for recovery of a high average yield of DNA (4.0 and 3.5 ug, respectively) with 260/280 ratios of 1.7 and 1.6, respectively, as determined by spectrophotometry. By comparison, specimens collected on treated cards yielded only 2.6 ug of DNA which had a 260/280 ratio of 1.1 indicating the likely presence of protein contaminants. A 7 d room temperature delay in processing of mouthwash procured specimens resulted in a 50% decline in DNA yield compared to those stored for 2 d. Delayed processing did not alter DNA yield of specimens collected by treated cards or cytobrush. Electrophoresis of DNA isolated from mouthwash and cytobrush specimens showed the presence of high molecular weight DNA (23 kb) as well as a broad size range smear. Electrophoresis of DNA isolated from specimens collected with treated cards did not show any visible bands or smears. PCR amplification of a 483 bp fragment of the myelperoxidase gene was obtained in 98.3% of cytobrush and mouthwash collected specimens and 96.3% of specimens collected using treated cards. Amplification of a 5 kb fragment was only possible in 60% of mouthwash samples and 40% cytobrush samples when 5 specimens were analyzed. SNP analysis by restriction fragment length polymorphism was possible in all 5 tested cytobrush and mouthwash specimens, but not in any of the treated cards specimens partially due to low PCR signal.
Biospecimens
CellBuccalFluidSalivaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
DNASpectrophotometryDNAElectrophoresisDNAPCRDNASNP assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of cell acquisition Cytological brushSwishing with water and expectorationTreated cardBiospecimen Acquisition Method of fluid acquisition Cytological brushSwishingTreated cardStorage Storage duration 2 d5 d7 dPCR Specific Length of gene fragment 481 bp5 kb
Purpose
The purpose of this study was to compare DNA quantification by picogreen (fluorometry) and spectrophotometry using buccal cells obtained by water mouthwash and cytobrush.
Summary of Findings
Quantification of total DNA yield by picogreen identified 46% as much DNA as was found by spectrophotometer in specimens collected by cytobrush and 87% as much when the biospecimen was collected by mouthwash. The authors attribute quantitative differences in DNA yield between methodologies to the spectrophotometric measurement quantifying degraded DNA, RNA and single stranded DNA along with the intact double stranded DNA. The average quantity of DNA obtained by cytobrush as quantified by picogreen was consistent between this study and three larger studies indicating that picogreen quantification is quite robust between users. The authors conclude that picogreen is the method of choice for DNA quantification due to its precision and accuracy.
Biospecimens
CellBuccalFluidSalivaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
DNAFluorometryDNASpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of cell acquisition Cytological brushSwishing with water and expectorationBiospecimen Acquisition Method of fluid acquisition Cytological brushSwishingSpectrophotometry Specific Technology platform FluorometrySpectrophotometry